$ 912.00Ex works
Adopt MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds. Support 4-20mA, RS485 and switch output, can be operated by remote control without opening the lid, with sound and light alarm and a variety of wireless transmission methods.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048742
Service :The delivery and service By NBCLab.Com
Methyl sulfide detector (model GY/VGD-200-C2H6S-G (0-10ppm)) is a low-power Modular design using MCU chip, with intelligent Sensor detection technology, integral flameproof (d) structure, fixed Installation method gas concentration detector. Standard configuration includes LCDTFT high definition LCD display, three-wire 4~ 20mA analog, RS485 digital and switching signal output, support customized products and Output signal fine-tuning, easy system networking and maintenance.
1. Customizable Range Intelligent Sensor with High Sensitivity, High Accuracy, Linear Stability and Fast Response. 2. Using MCU chip, low power consumption, safe and reliable performance, accurate data conversion, stable signal output. 3. Support 4-20mA, RS485, switch and other signal output, can be connected to PLC, DCS, DDC and other industrial control systems or linkage control equipment. 4. Customizable wireless signal transmission, such as Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc. 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched. 6. Support remote control operation without opening the lid, including alarm value setting, zero adjustment, calibrate, reset, modify the address code, etc. 7. Local sound and light alarm, support remote alarm prompt and infrared remote control one-button muffler. 8. Aluminum alloy cast explosion-proof shell, sturdy and durable. 9. Passed a variety of international certifications, such as CMA, CNAS, CE, ROHS, SIL, UL, ECM, etc. 10. Explosion-proof level is Ex db IIC T6 Gb, explosion-proof certificate number SYEx23.04100.
Based on the principle of catalytic combustion detection, methyl sulfide detector detects gas concentration through diffusion Sampling method. Intelligent Sensor and MCU chip are used to process data to ensure detection accuracy and Stability.
Workplace environment Gas detection, explosive environment monitoring, flammability dust environment monitoring, industrial process control, safety alarm system
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the tester to ensure that the electrical interfaces and cables are connected correctly. Connect the Power Supply (DC24V). 3. Use the remote control to set the alarm value, zero, calibrate, reset or modify the address code. 4. Monitor gas concentration data on the LCDTFT display. 5. Connect Output signal to Control system or alarm device as needed.
• Operating ambient temperature range is -20~ 50 ℃, Humidity is 10-95% RH (no condensation). • Sensor life is 2 to 3 years, depending on the Operating Environment. • When connecting the cable, choose three-core Shielding cable for 4~ 20mA, four-core for RS485, and when the distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm. Shielding layer needs to be grounded. • The explosion-proof form is explosion-proof to ensure safe use in dangerous places. Alarm settings support regular high and low alarms and interval control alarms. • Optional Accessories such as Power Adapters and monitoring accessories need to be configured according to requirements.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.