$ 912.00Ex works
Adopt MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds; support 4-20mA, RS485 and switch output, can be operated by infrared remote control without opening the lid, with local sound and light alarm and remote alarm function.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048743
Service :The delivery and service By NBCLab.Com
GUOYUGRA GY/VGD-200-C2H6O4S-G (0-10ppm) dimethyl sulfate detector is a low-power Modular design using MCU chip, with intelligent Sensor detection technology, overall flameproof (d) structure, fixed Installation method detector. Standard configuration is LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, provide customized products according to user requests, and also support Output signal fine-tuning and other functions to facilitate system networking and maintenance.
1. Adopt Customizable Range Intelligent Sensor, which guarantees the advantages of high Sensitivity, high accuracy, linear stability and fast Response of the detector; 2. The use of MCU chip highlights the low power consumption of the detector, safe and reliable performance, accurate data conversion, stable signal output, etc.; 3.4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, can also be a single machine through the switch linkage fan, solenoid valve and other control equipment; 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.; 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched; 6. The detector can be operated by remote control without opening the lid to perform function menu operations such as alarm value, zero adjustment, calibrating, reset, and modification of the address code; 7. Local integrated sound and light alarm indication, remote mobile phones, computers, monitoring rooms, third-party platforms and other alarm prompts can be realized through alarm control host or wireless signal, and infrared remote control can also be silenced with one click; 8. Aluminum alloy cast body explosion-proof shell, sturdy and durable; 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications; 10. Explosion-proof certificate grade: Ex db IIC T6 Gb; explosion-proof certificate number: SYEx23.04100.
The detection principle is catalytic combustion, and the Sampling method is diffusion type. The gas concentration is detected by the intelligent Sensor and the data is converted into electrical signal output.
Workplace environment Gas detection, Industrial Control system, Electrical installation in hazardous places, Dust flammability environment, Hazardous factors monitoring in the workplace
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the detector to ensure that the electrical interface is connected correctly. 2. Connect the power supply, Operating voltage is DC24V (12V~ 30V); 3. Set the alarm value, zero, calibrate, reset, modify the address code and other parameters through the remote control or Operating interface; 4. Start detection and monitor gas concentration; 5. Output signal access to PLC, DCS, DDC and other systems or linkage control equipment; 6. Regularly maintain and calibrate Sensors to ensure detection accuracy.
• Operating ambient temperature range is -20~ 50 ℃, Humidity is 10-95% RH (no condensation); • Sensors have a lifespan of 2 to 3 years and need to be replaced regularly according to the Operating Environment; • When connecting the cable, choose three-core Shielding cable for 4~ 20mA, four-core for RS485, and when the distance exceeds 1000 meters, the diameter of a single wire is ≥ 1.5mm. Shielding layer needs to be connected to the earth; • Wireless transmission can be equipped with built-in or external modules, and remote data transmission requires a cloud platform; • Alarm settings support conventional high and low alarms and interval control alarms, with standard two-level alarms; • The explosion-proof form is Probe Transmitter and Sensor are flameproof to ensure safe use in dangerous environments; • Optional Accessories such as Power Adapters and computer monitoring accessories need to be configured according to requirements.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.