$ 499.00Ex works
Adopt MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support 4-20mA, RS485 and switch output, can be operated by remote control without opening the lid, with sound and light alarm function.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048757
Service :The delivery and service By NBCLab.Com
The acetylene detector is a GY/VGD-200-C2H2-G (0-10ppm) model product produced by GUOYUGRA. It adopts MCU chip low-power Modular design, with intelligent Sensor detection technology, overall flameproof (d) structure, fixed Installation method. Standard configuration includes LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, supports customized products and Output signal fine-tuning, which is convenient for system networking and maintenance.
1. Customizable Range Intelligent Sensor, High Sensitivity, High Accuracy, Linear Stability, Fast Response 2. Using MCU chip, low power consumption, safe and reliable performance, accurate data conversion, stable signal output 3. Support 4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, single linkage fan, solenoid valve and other control equipment 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched 6. The alarm value, zero adjustment, calibrate, reset, modify the address code and other function menu operations can be carried out by remote control without opening the lid 7. Local integrated sound and light alarm indication, support remote mobile phone, computer, monitoring room, third-party platform alarm prompt, infrared remote control one-click muffler 8. Aluminum alloy cast explosion-proof shell, sturdy and durable 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications 10. Explosion-proof level Ex db IIC T6 Gb, explosion-proof certificate number SYEx23.04100
The acetylene detector adopts the principle of catalytic combustion detection and detects the gas concentration through the diffusion Sampling method. The Sensor is based on the catalytic combustion effect. When the acetylene gas contacts the Sensor, it reacts and produces electrical signal changes, which are processed by the MCU chip and converted into concentration data output.
Workplace environment Gas detection, explosive environment monitoring, flammability dust environment monitoring, industrial process control, safety alarm system
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the detector and select the appropriate position to fix it. 2. Operating voltage DC24V (12V~ 30V) 3. Connect Output signal cable as required: 3-core Shielding cable for 4~ 20mA, 4-core cable for RS485 4. Set the alarm value, zero adjustment, calibrate, reset, modify the address code and other functions through the remote control without opening the lid 5. Start the detector and observe the LCDTFT display to confirm the working status 6. Connect external devices such as PLCs, DCS, alarms, etc. as required 7. Regularly calibrate and maintain to ensure Sensor performance
• Operating ambient temperature range -20~ 50 ℃, Humidity 10-95% RH (non-condensing) • Sensor life 2~ 3 years, depending on the Operating Environment, need to be replaced regularly • When the connection cable distance exceeds 1000 meters, the single wire diameter must be ≥ 1.5mm, and the Shielding layer must be grounded • The explosion-proof form is Probe Transmitter and Sensor are explosion-proof, which need to be installed strictly according to the explosion-proof requirements • Optional Accessories such as Power Adapter, Conversion Cable, etc. Measurement certificate fee is paid by the user • Alarm settings support conventional high and low alarms and interval control alarms, which need to be reasonably configured • Wireless transmission module is optional, remote data transmission requires external GPRS/4G module • Electrical interface default M20X1.5 internal thread, optional 3/4NPT, 1/2NPT
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.