$ 435.00Ex works
Adopt MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds. Support 4-20mA, RS485 and switch output, can be operated without opening the lid through infrared remote control, with local sound and light alarm and remote monitoring capabilities.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048777
Service :The delivery and service By NBCLab.Com
Trichloroethylene detector is a GY/VGD-200-C2HCL3-G (0-50ppm) model gas concentration detector produced by GUOYUGRA. It adopts MCU chip low power consumption Modular design, with intelligent Sensor detection technology, overall flameproof (d) structure, fixed Installation method. Standard configuration includes LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, support customized products and Output signal fine-tuning, easy system networking and maintenance.
1. Customizable Range Intelligent Sensor, High Sensitivity, High Accuracy, Linear Stability, Fast Response 2. Using MCU chip, low power consumption, safe and reliable performance, accurate data conversion, stable signal output 3. Support 4-20mA, RS485, switch and other signal output, can be connected to PLC, DCS, DDC and other industrial control systems or stand-alone linkage control equipment 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched 6. Alarm value, zero adjustment, calibrate, reset, modify address code and other operations can be carried out by remote control without opening the lid 7. Local integrated sound and light alarm indication, support remote alarm prompt and infrared remote control one-button muffler 8. Aluminum alloy cast explosion-proof shell, sturdy and durable 9. Passed CMA, CNAS, CE, ROHS, SIL, UL, ECM and other international certifications 10. Explosion-proof level Ex db IIC T6 Gb, explosion-proof certificate number SYEx23.04100
The trichloroethylene detector adopts the principle of catalytic combustion detection and detects gas concentration by diffusion Sampling method. Sensor converts gas concentration into electrical signal, processed by MCU chip, and outputs 4~ 20mA analog, RS485 digital or switching signal to realize gas concentration monitoring and alarm function.
Industrial environment Gas detection, workplace safety monitoring, explosive environment monitoring, harmful gas alarm
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the detector to ensure that the electrical interface is connected correctly 2. Connect DC24V Power Supply 3. Set the alarm value, zero adjustment, calibrating and other parameters through the remote control or Operating interface 4. Start the detector and monitor the gas concentration display 5. Connect PLC, DCS, DDC and other Control systems or linkage equipment as needed 6. Regular maintenance and calibrating
• Operating voltage range is DC12V~ 30V to ensure stable power supply • Ambient Temperature -20~ 50 ℃, Humidity 10-95% RH (non-condensing) • Sensor life 2~ 3 years, need to be replaced regularly according to the Operating Environment • Connecting cable selection: 4~ 20mA choose three-core Shielding cable, RS485 choose four-core, when the distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm, and the Shielding layer is connected to the earth • The explosion-proof form is explosion-proof, and the installation must meet the explosion-proof requirements • Wireless transmission is optional, remote data transmission requires an external module • Alarm settings support conventional high and low alarms and interval control alarms • Optional Accessories include Power Adapter and Computer Monitoring Accessories at the user's own expense
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.