$ 965.00Ex works
Using infrared NDIR detection principle, range 0-8% Vol, Response Time ≤ 30S, support 4-20mA, RS485 and switch output, Modular design is convenient for System integration and maintenance.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048780
Service :The delivery and service By NBCLab.Com
Chloromethane detector (infrared) is a GY/VGD-200-CH3CL-G (0-8% Vol) model gas concentration detector produced by GUOYUGRA. It adopts MCU chip low-power Modular design and has intelligent Sensor detection technology, overall flameproof (d) structure and fixed Installation method. Standard configuration includes LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, support customized products and Output signal fine-tuning, easy system networking and maintenance.
1. Customizable Range Intelligent Sensor, High Sensitivity, High Accuracy, Linear Stability, Fast Response 2. Using MCU chip, low power consumption, safe and reliable performance, accurate data conversion, stable signal output 3. Support 4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, or stand-alone linkage fan, solenoid valve and other control equipment 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched 6. The alarm value, zero adjustment, calibrate, reset, modify the address code and other function menu operations can be carried out by remote control without opening the lid 7. Local integrated sound and light alarm indication, support remote mobile phone, computer, monitoring room, third-party platform alarm prompt, infrared remote control one-click muffler 8. Aluminum alloy cast explosion-proof shell, sturdy and durable 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications 10. Explosion-proof certificate grade: Ex db IIC T6 Gb; explosion-proof certificate number: SYEx23.04100
The detector adopts the principle of infrared NDIR detection and detects the gas concentration through the diffusion Sampling method. The Sensor converts the detected gas concentration signal into an electrical signal, which is processed by the MCU chip, and outputs standard signals such as 4-20mA, RS485 or switching quantity to achieve accurate monitoring and alarm of gas concentration.
Industrial Gas detection, environment monitoring, safety protection, chemical production, dangerous place monitoring
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the tester to ensure that the electrical interface is properly connected to the cable 2. Power Supply DC24V 3. Set the alarm value, zero adjustment, calibrating and other parameters through the remote control or local interface 4. Start the detector and monitor the gas concentration data on the LCDTFT display 5. Connect Output signals to PLC, DCS and other Control systems or remote platforms as needed
* Operating voltage range is DC12V~ 30V to ensure stable power supply * Working Ambient Temperature -20~ 50 ℃, Humidity 10-95% RH (non-condensing) * Use three-core Shielding cable for 4~ 20mA output, RS485 uses four-core cable, when the transmission distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm, and the Shielding layer needs to be grounded The explosion-proof form is explosion-proof, and the installation and maintenance must comply with the explosion-proof requirements * Sensor life is about 10 years, the actual life depends on the Operating Environment * Optional Measurement Certificate, user pays * Wireless transmission module is optional, pay attention to signal coverage and Stability when installing
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.