$ 538.00Ex works
The MCU chip is used to achieve low power consumption operation, with detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support for 4-20mA and RS485 output, explosion-proof structure and remote alarm function.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048782
Service :The delivery and service By NBCLab.Com
GUOYUGRA GY/VGD-200-CH2CL2-G (0-50ppm) dichloromethane detector is a low-power Modular design using MCU chip, with intelligent Sensor detection technology, overall flameproof (d) structure, fixed Installation method detector. The standard configuration is LCDTFT high definition LCD display, three-wire 4~ 20mA analog, RS485 digital and switching signal output, support customized products and Output signal fine-tuning, convenient system networking and maintenance.
1. Customizable Range Intelligent Sensor, High Sensitivity, High Accuracy, Linear Stability, Fast Response 2. Using MCU chip, low power consumption, safe and reliable performance, accurate data conversion, stable signal output 3. Support 4-20mA, RS485, switch and other signal output, can be connected to PLC, DCS, DDC and other industrial control systems 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched 6. Alarm value, zero adjustment, calibrate, reset, modify address code and other functions can be performed by remote control without opening the lid 7. Local integrated sound and light alarm indication, support remote alarm prompt and infrared remote control one-button muffler 8. Aluminum alloy cast explosion-proof shell, sturdy and durable 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications 10. Explosion-proof level: Ex db IIC T6 Gb, explosion-proof certificate number: SYEx23.04100
The detector adopts the principle of catalytic combustion detection and detects gas concentration through diffusion Sampling method. Intelligent Sensor technology combined with MCU chip processing realizes accurate data conversion and stable signal output.
Dichloromethane detection, toxic gas monitoring, industrial environment safety testing, workplace environment monitoring, explosion-proof environment Gas detection
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the detector to ensure that the electrical interface is connected correctly 2. Connect DC24V Power Supply 3. Set the alarm value, zero adjustment, calibrating and other parameters through the remote control or Operating interface 4. Select Output signal type (4-20mA, RS485, switch, etc.) 5. Connect receiving devices (computers, control alarms, PLCs, DCS, DDC, etc.) 6. Start the detector and observe the LCDTFT display reading 7. Set Alarm mode and linkage control device as needed
• Operating voltage range is DC12V~ 30V, please ensure stable power supply • Working Ambient Temperature -20~ 50 ℃, Humidity 10-95% RH (non-condensing) Sensor life is 2-3 years depending on Operating Environment • Connecting cable selection: 4~ 20mA choose three-core Shielding cable, RS485 choose four-core, when the distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm. • Shielding must be connected to the earth • The explosion-proof form is explosion-proof type, please install and use it in strict accordance with the explosion-proof requirements • Regular calibrating and maintenance to ensure detection accuracy • Wireless transmission function is optional, and corresponding modules need to be configured according to actual needs
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.