$ 1220.00Ex works
Using infrared NDIR detection principle, detection error ≤ +/- 1% F. S, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output, support remote data transmission and intelligent Sensor technology, Sensor life up to 10 years.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048809
Service :The delivery and service By NBCLab.Com
The gas concentration detector is a low-power Modular design using MCU chip, with intelligent Sensor detection technology, overall flameproof (d) structure, and fixed Installation method. The standard configuration is LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, customized products are provided according to user requests, and Output signal fine-tuning is also supported, which is convenient for system networking and maintenance.
1. Adopt Customizable Range Intelligent Sensor, which guarantees the advantages of high Sensitivity, high accuracy, linear stability and fast Response of the detector; 2. The use of MCU chip highlights the low power consumption of the detector, safe and reliable performance, accurate data conversion, stable signal output, etc.; 3.4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, can also be a single machine through the switch linkage fan, solenoid valve and other control equipment; 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.; 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched; 6. The detector can be operated by remote control without opening the lid to perform function menu operations such as alarm value, zero adjustment, calibrating, reset, and modification of the address code; 7. Local integrated sound and light alarm indication, remote mobile phones, computers, monitoring rooms, third-party platforms and other alarm prompts can be realized through alarm control host or wireless signal, and infrared remote control can also be silenced with one click; 8. Aluminum alloy cast body explosion-proof shell, sturdy and durable; 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications; 10. Explosion-proof certificate grade: Ex db IIC T6 Gb; explosion-proof certificate number: SYEx23.04100.
The detector adopts the principle of infrared NDIR detection and detects the gas concentration through the diffusion Sampling method.
User computer, control alarm, PLC, DCS, DDC, etc
GB/T3836.1-2021 "Explosive environment Part 1: General requirements", GB/T3836.31-2021 "Explosive environment Part 31: Equipment protected by anti-dust ignition enclosure" t ", GB3836.15-2000" Electrical equipment for explosive gas environment Part 15: Electrical installation in hazardous places (except coal mines) ", GB 1 2476.1 - 20 1 3" Electrical equipment for flammability dust environment Part 1: General requirements ", GB12358-2006" General technical requirements for workplace environment Gas detection alarms ", GBZ2.1-2007" Occupational exposure limits for hazardous factors in the workplace ", GB4208-2008" Shell Protection Rating (IP code) "
1. Carry out function menu operations such as alarm value, zero adjustment, calibrate, reset, and address code modification of the detector through remote control without opening the lid; 2. Optional Accessories such as 220V to 24V Power Adapter for installation; 3. Connection cable: For 4~ 20mA choose three-core Shielding cable, RS485 choose four-core, when the distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm, and the Shielding layer is connected to the earth; 4. Wireless transmission: Built-in LORA, Zigbee module for short-range wireless transmission, or external GPRS/4G module for remote data transmission to the cloud platform.
• Operating voltage is DC24V (12V~ 30V), make sure the Power Adapter matches; • Working Ambient Temperature -20~ 50 ℃, Humidity 10-95% RH (no condensation), avoid using beyond the range; • Sensor life is 10 years, but depending on the environment used, it needs to be checked regularly; • The explosion-proof form is Probe Transmitter and Sensor are explosion-proof, and the installation must meet the explosion-proof requirements; • When the connection cable distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm, and the Shielding layer must be connected to the earth; • Alarm settings support conventional high and low alarms and interval control alarms, which need to be configured according to actual needs; • Optional Accessories such as Measurement Card fee paid by the user, need to confirm in advance; • Output signal voltage output and current output choose one to avoid simultaneous use.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.