$ 1220.00Ex works
Using NDIR detection principle, range 0-1000ppm, resolution 1ppm, Response Time ≤ 30S, with flameproof structure and a variety of signal output, support remote monitoring and customization functions.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048814
Service :The delivery and service By NBCLab.Com
The gas concentration detector is a low-power Modular design using MCU chip, with intelligent Sensor detection technology, overall flameproof (d) structure, and fixed Installation method. The standard configuration is LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, customized products are provided according to user requests, and Output signal fine-tuning is also supported, which is convenient for system networking and maintenance.
1. Adopt Customizable Range Intelligent Sensor, which guarantees the advantages of high Sensitivity, high accuracy, linear stability and fast Response of the detector; 2. The use of MCU chip highlights the low power consumption of the detector, safe and reliable performance, accurate data conversion, stable signal output, etc.; 3.4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, can also be a single machine through the switch linkage fan, solenoid valve and other control equipment; 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.; 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched; 6. The detector can be operated by remote control without opening the lid to perform function menu operations such as alarm value, zero adjustment, calibrating, reset, and modification of the address code; 7. Local integrated sound and light alarm indication, remote mobile phones, computers, monitoring rooms, third-party platforms and other alarm prompts can be realized through alarm control host or wireless signal, and infrared remote control can also be silenced with one click; 8. Aluminum alloy cast body explosion-proof shell, sturdy and durable; 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications; 10. Explosion-proof certificate grade: Ex db IIC T6 Gb; explosion-proof certificate number: SYEx23.04100.
The detector adopts the principle of infrared NDIR detection and detects gas concentration by diffusion Sampling method.
Gas concentration detection, industrial process control, environment monitoring, safety alarm system
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the detector to ensure that the electrical interface is connected correctly. 2. Connection cable: 4~ 20mA choose three-core Shielding cable, RS485 choose four-core, when the distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm, and the Shielding layer is connected to the earth; 3. Optional wireless transmission: built-in LORA, Zigbee module or external GPRS/4G module; 4. Set the alarm value, zero adjustment, calibrate, reset and modify the address code through the remote control free opening lid; 5. Start the detector to monitor the gas concentration; 6. Handle alarm events according to alarm settings; 7. Regularly maintain and calibrate Sensors.
• Operating voltage is DC24V (12V~ 30V) to ensure stable power supply; • Working Ambient Temperature -20~ 50 ℃, Humidity 10-95% RH (non-condensing); • Sensor life is about 10 years, depending on the Operating Environment; • Explosion-proof form Probe Transmitter and Sensor are flameproof; • When connecting the cable, the distance exceeding 1000 meters requires a single wire diameter ≥ 1.5mm, and the Shielding layer must be connected to the earth; • Alarm settings support conventional high and low alarms and interval control alarms; • Optional Accessories such as Power Adapters and computer monitoring accessories need to be configured on demand; • Measurement certificate is optional, the user pays the fee; • Output signals and alarm functions are checked regularly to ensure the normal operation of the system.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.