$ 474.00Ex works
Modular design with low power consumption, Explosion-proof level Ex db IIC T6 Gb, Protection Rating IP66, support 4-20mA and RS485 signal output, Response Time ≤ 30 seconds, can be operated by remote control without opening the lid.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048828
Service :The delivery and service By NBCLab.Com
The online all-in-one detector is a detection instrument with low power consumption Modular design, intelligent Sensor detection technology, overall flameproof (d) structure, and fixed Installation method. The standard configuration is LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output. Provide customized products according to user requests, and also support Output signal fine-tuning and other functions, which is convenient for system networking and maintenance. The rugged and durable explosion-proof shell of the online all-in-one detector is widely used in petroleum, chemical industry, metallurgy, fire protection, coal mine, cement, lame plating, metal sanding, electric power, ship, environmental protection, telecommunications, biochemical medical and other industries.
1. Adopt Customizable Range Intelligent Sensor, which guarantees the advantages of high Sensitivity, high accuracy, linear stability and fast Response of the detector; 2. The use of MCU chip highlights the low power consumption of the detector, safe and reliable performance, accurate data conversion, stable signal output, etc.; 3.4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, can also be a single machine through the switch linkage fan, solenoid valve and other control equipment; 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.; 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched; 6. The detector can be operated by remote control without opening the lid to perform function menu operations such as alarm value, zero adjustment, calibrating, reset, and modification of the address code; 7. Local integrated sound and light alarm indication, remote mobile phones, computers, monitoring rooms, third-party platforms and other alarm prompts can be realized through alarm control host or wireless signal, and infrared remote control can also be silenced with one click; 8. Aluminum alloy cast body explosion-proof shell, sturdy and durable; 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications; 10. Explosion-proof certificate grade: Ex db IIC T6 Gb; 11. Protection Rating: IP66.
Sensor detection technology, based on the principle of catalytic combustion and electrochemistry, is used to detect gas through diffusion or optional pump-suction Sampling method. The instrument processes data through MCU chip to achieve accurate signal output and stable performance.
Petroleum, chemical industry, metallurgy, fire protection, coal mine, cement, lame plating, metal sanding, electric power, marine, environmental protection, telecommunications, biochemical medical
GB/T3836.1-2021 "Explosive environment Part 1: General requirements", GB/T3836.31-2021 "Explosive environment Part 31: Equipment protected by anti-dust ignition enclosure" t ", GB3836.15-2000" Electrical equipment for explosive gas environment Part 15: Electrical installation in hazardous places (except coal mines) ", GB 1 2476.1 - 20 1 3" Electrical equipment for flammability dust environment Part 1: General requirements ", GB12358-2006" General technical requirements for workplace environment Gas detection alarms ", GBZ2.1-2007" Occupational exposure limits for hazardous factors in the workplace ", GB4208-2008" Shell Protection Rating (IP code) "
1. Set the alarm value of the detector by remote control without opening the lid; 2. Zero the detector by remote control without opening the lid; 3. The detector is calibrated by remote control without opening the lid; 4. Reset the detector by remote control without opening the lid; 5. Modify the address code operation of the detector by remote control without opening the lid; 6. Use infrared remote control to muffle sound with one click.
• Operating voltage range is DC12V~ 30V, DC24V is recommended; • Working Ambient Temperature -20~ 50 ℃; • Environmental humidity of 10-95% RH (non-condensing); • Sensor life is 2 to 3 years, depending on the Operating Environment; • Connecting cable selection: 4~ 20mA choose three-core Shielding cable, RS485 choose four-core, when the distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm, and the Shielding layer is connected to the earth; • Wireless transmission can choose built-in LORA, Zigbee module or external GPRS/4G module; • Electrical interface default M20X1.5 internal thread, optional 3/4NPT, 1/2NPT; • Optional Accessories include 220V to 24V Power Adapter, computer monitoring accessories, etc.; • Output signal includes 4-20mA, RS485, voltage signal, switching signal and wireless signal, which need to be selected according to demand; Alarm settings support regular high and low alarms and interval control alarms.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.