The range covers 20 to 100,000 mPa · s, repRoducibility up to +/- 0.5% F. S, Thermostatic Bath with four-speed Rotation speed and intelligent PID temperature control, Temperature Fluctuation is only +/- 0.05~ 0.1 ℃, support internal and external circulation, to meet the needs of accurate viscosity testing.
Category : Rotational Viscometer
Brand : JingTian
SKU : NB049016
Service :The delivery and service By NBCLab.Com
The HuiNuo NDJ-5S + LC-1008 Thermostatic bath is a digital Rotational Viscometer with an LCD display that displays information such as viscosity, Rotation speed, percentile torque, rotor number and the maximum viscosity value measurable at the current Rotation speed of the selected rotor. Measurement ranges from 20 to 100,000 mPa · s and is equipped with a Thermostatic bath for accurate temperature control measurement.
1. LCD display, comprehensive information, including viscosity, Rotation speed, percentile torque, rotor number and maximum measurable viscosity value. 2. Wide viscosity measurement range, 20~ 100000mPa · s. 3. Equipped with LC-1008 Thermostatic bath, Temperature range -10~ 100 ℃, Temperature Fluctuation is small. 4. Good reproducibility, +/- 0.5% F.S. 5. Measurement accuracy is high, +/- 1% F.S. 6. Rotation speed of four gears is adjustable, respectively 6, 12, 30, 60rpm. 7. Thermostatic bath with internal and external circulation function, pump Flow rate of 12L/min.
The digital Rotational Viscometer is based on the swirl/spin method for the measurement of fluid viscosity. The motor drives the rotor to swirl/spin uniformly in the fluid, and the rotor is subjected to a Tack resistance moment proportional to the viscosity of the fluid. The instrument directly displays the viscosity value of the fluid by measuring the resistance moment and performing internal calculations. With the Thermostatic bath, the sample can be measured at a set temperature, improving the accuracy and Repeatability of the results.
Petrochemicals, Paint inks, Food and Medicine, Cosmetics, Adhesives, Research and Education
JJF 1030-2010
1. Place the instrument on a stable bench and connect the Power Adapter. 2. According to the estimated sample viscosity, choose the appropriate rotor and Rotation speed combination. 3. Install the rotor and ensure that it is vertically immersed in the sample to the designated marking line. 4. For thermostatic measurement, place the sample in a Thermostatic bath, set and wait for the temperature to reach the target value. 5. Turn on the Viscometer power and select the set Rotation speed. 6. After the display value is stable, read and record the viscosity value. 7. After the measurement is complete, turn off the power, remove the rotor and clean it.
* The instrument should be placed in a stable and vibration-free working environment. * Do not operate in an environment exceeding the allowable Operating temperature (5~ 32 ° C) and Humidity (80%). * When selecting the rotor and Rotation speed, ensure that the Measured value is within the maximum measurable viscosity range of the selected combination for optimum accuracy. * When the rotor is immersed in the sample, bubbles should be avoided and the immersion depth should be accurate. * Before and after each use, the rotor should be thoroughly cleaned to prevent cross-contamination or drying of the sample from affecting the measurement. * When connecting the Thermostatic bath, ensure that the circulation line is connected correctly and free of leakage. The continuous operation time of the instrument should not exceed 100 hours. * Please use the original dedicated Power Adapter.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.