Viscosity measurement range of 80 to 40000000 mPa · s, equipped with stepless transmission function, Rotation speed 0.1-99 rpm, Thermostatic Bath with intelligent PID temperature control, Temperature Fluctuation is small, ensuring Test accuracy and Stability under different temperature conditions.
Category : Rotational Viscometer
Brand : JingTian
SKU : NB049018
Service :The delivery and service By NBCLab.Com
The RVDV-1 + LC-1008 Thermostatic bath digital Rotational Viscometer is a high-performance laboratory measuring instrument designed for accurate measurement of fluid viscosity. Its viscosity measurement range is wide, from 80 to 40,000,000 mPa · s, which can meet the testing needs of a variety of complex fluids. Operating interface allows clear display of detailed information such as viscosity, Rotation speed, temperature, percentile torque, rotor number, and the maximum measurable viscosity value of the selected rotor at the current Rotation speed, making it easy to operate and intuitive to read data. The LC-1008 Thermostatic bath uses intelligent PID temperature control technology to ensure High Accuracy viscosity testing under different temperature conditions.
1. Wide viscosity measurement range, up to 80~ 40,000,000 mPa · s. 2. Digital Display Operating interface, displaying comprehensive information, including viscosity, Rotation speed, temperature, percentile torque, rotor number and the maximum viscosity value of the selected rotor at the current Rotation speed. 3. Equipped with continuously variable speed function, Speed range is 0.1~ 99.9rpm, to achieve accurate measurement. 4. Supporting LC-1008 Thermostatic bath, using intelligent PID temperature control, Temperature range -10 ℃ to 100 ℃, Temperature Fluctuation is only +/- 0.05~ 0.1 ℃. 5. Thermostatic bath with internal and external circulation function, pump Flow rate 12L/min, effectively ensure the temperature uniformity in the tank. 6. Thermostatic bath is equipped with low liquid level alarm, pressure/suction pump and other safety and auxiliary features to ensure safe and stable use. 7. reproducibility is +/- 0.5% F.S. Measurement accuracy is +/- 1% F.S.
The digital Rotational Viscometer is based on the swirl/spin method for fluid viscosity measurement. The instrument drives the rotor to swirl/spin uniformly in the fluid to be measured. The viscosity value of the fluid is calculated by measuring the Tack resistance torque of the rotor and based on the set Rotation speed, rotor specifications and other parameters. The matching Thermostatic bath precisely controls the sample temperature through the intelligent PID temperature control system, and ensures that the temperature in the Tank is highly uniform through the internal and external circulation system, so as to achieve accurate measurement of fluid viscosity under different temperature conditions.
Chemical, food, and materials science
JJF 1030-2010
1. Connect the instrument power supply, turn on the Viscometer host and Thermostatic bath. 2. According to the estimated viscosity value of the sample to be tested, select the appropriate rotor and install it. 3. Place the measurement cup containing the sample in the Thermostatic bath, ensuring that the rotor is immersed in the sample to the designated marking line. 4. Set the required test temperature on the Thermostatic bath, start the temperature control and circulation system, and wait for the temperature to stabilize. 5. Set the desired Rotation speed on the Viscometer host. 6. Start the Viscometer to start the measurement, and record the displayed viscosity value and Miscellaneous parameter after the reading is stable. 7. After the measurement is complete, turn off the instrument, remove the rotor and clean it.
The instrument should be placed on a stable countertop to avoid vibration. * Power supply voltage meets the requirements before use (Viscometer host uses dedicated Power Adapter, Thermostatic bath power supply is 200~ 230VAC, 50Hz). * When selecting a rotor, ensure that the estimated sample viscosity value is within the measurable range of the rotor and Rotation speed. When installing and removing the rotor, care should be taken to avoid bending or damaging the shaft. * Inject enough heat conducting medium into the Thermostatic bath Tank, and pay attention to the low liquid level alarm prompt to prevent dry burning. The continuous operation time of the instrument should not exceed 100 hours. * Operating Environment temperature should be between 5~ 32 ℃, relative humidity does not exceed 80%. * After the measurement is completed, the rotor and measurement cup should be cleaned in time to prevent residual corrosion of the sample or affect the next Measurement accuracy. Do not move or shake the device violently while the instrument is running.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.