Overview
DR82A Optical inspection transmittance tester is a Benchtop Optical inspection transmittance measuring instrument. It adopts a three-in-one parallel light path design and can measure visible light transmitance, infrared transmittance and ultraviolet transmittance at one time. The instrument is specially used for the measurement of Optical inspection transmittance of Glass, Coating Materials, Solar Films, Insulation Films, Acrylic and Organic Materials. The test aperture is 1.3mm. It is suitable for the measurement of small sizes and thicker materials. It has the characteristics of instant measurement, fast and accurate. The exquisite and compact design is suitable for field and laboratory environments.
Features
1. Three-in-one Illuminant design, three-way transmittance data can be obtained in one measurement, easy to operate and time-saving
2. Parallel light design to ensure stable and accurate measurement results of large thickness materials
3.1.3Mm test aperture, suitable for small size material transmittance testing
4. With real-time automatic measurement and dynamic Automatic calibration function, Automatic calibration to 100% transmittance
5. Comes with Type-C interface, which can be connected to a computer for data transmission
6. Provide continuous (CONTINUE) and single (SINGLE) two measurement modes
7. There is a beep during the operation (Single Measurement mode)
8. Mass storage, capable of storing 10 sets of data, 200 in each group, for a total of 2,000
9.5 inch LCD color screen display
10. Support Chinese and English bilingual versions
11. It is powered by 5V power supply and can be connected to a mobile power supply (power bank) for use
Principle
The instrument adopts a three-in-one parallel light path design, and illuminates the test sample with built-in visible light (380-760nm), infrared light (940nm) and ultraviolet light (365nm) Illuminant light to measure the transmittance of the sample to different wavelengths of light. The parallel light design ensures stable ray of light path, suitable for measurement of thicker materials, the instrument has Automatic calibration function, Automatic calibration to 100% transmittance reference after startup, to achieve accurate measurement.
Applications
Measurement of various transparent and translucent light transmitances such as Glass, plastic, acrylic, film, etc., measurement of infrared transmission objects such as solar film, thermal insulation film, sunglasses, infrared filters/filter strips, remote control windows, measurement of ultraviolet transmittance, etc
Notice
• This instrument is not suitable for measurement of printing, milky white, matte material transmittance
• The instrument cannot be used in sunlight or strong light