$ 4200.00Ex works
Using SUS304 stainless steel inner box and ultra-fine fiberglass insulation system, equipped with Japan Panasonic Compressor and PID temperature control system, Temperature Uniformity ≤ 2 ℃, Humidity stability +/- 2% RH, support program test and Data storage function.
Category : Temperature Humidity Chamber
Brand : LUGONG
SKU : NB049197
Service :The delivery and service By NBCLab.Com
Lugong ST-100LD humidity chamber is mainly used to simulate the severe high temperature, low temperature or heat and humidity environment that may be encountered during transportation, storage and use of electronic Instruments, new materials, electricians, vehicles, metals, electronic products, aerospace materials, etc.; or under high temperature, low temperature, heat and humidity alternating environment, inspection materials, accessories or instruments are resistant to high temperature, cold, moisture and heat performance and possible damage life reduction.
1. The box adopts SUS304 #stainless steel inner box and Cold rolled steel plate paint outer box 2. Explosion-proof door handle design, easy and safe to operate 3.Ultra-fine fiberglass insulation system, refined silicone rubber sealing 4. Install high-quality fixed PU movable wheel at the bottom 5. SUS304 #stainless steel sample holder, load-bearing 25kg 6.Double-decked Vacuum Reinforced Glass Viewing Window with Heating Defrost 7. Using Japanese Panasonic Compressor and American DuPont environmental protection refrigerant 8. P.I.D + S.S.R Temperature and Humidity Coordinated Control system 9. Nickel-chromium alloy high-speed heating wire heating system 10. Built-in nickel-chromium alloy humidification system for stainless steel pipes 11. Precision LCD programmable temperature controller 12. Safety protection system
The equipment adopts thermal equilibrate temperature control mode, and coordinates the temperature and Humidity through the P.I.D + S.S.R system in the same channel. The refrigeration system uses Japanese Panasonic Compressor and American DuPont environmental protection refrigerant, and realizes precise temperature control through binary low temperature circuit system design. The heating system adopts nickel-chromium alloy high-speed heating wire, and the humidification system adopts stainless steel tube with nickel-chromium alloy high-speed heating wire to achieve rapid Response and stable control.
Electronic Instruments, New Materials, Electrical, Vehicles, Metals, Electronics, Aerospace Materials
GB2423.1-2008/IEC6008-2-1-2007、GB/T 2423.2-2008、GJB150.3A-2009、GJB150.4A-2009、GB2423.22-2008、GBT 2424.5-2006、GB/T 10589-2008、GB/T2423.3-2008(IEC68-2-3)
1. Move the device to the designated position and fix the casters 2. Connect the power supply (single-phase 220V) 3. Set test parameters through Touchscreen 4. Select the program mode or the fixed value mode to run 5. Monitor the test process through the observation window 6. Automatic shutdown after the test is completed
• Check the power connection before the equipment runs • Sample load-bearing should be evenly distributed, no more than 25kg • Regularly check the automatic hydration device of the humidification system • Pay attention to the operating status indicator light of the equipment • The equipment will automatically shut down after the fault alarm • Confirm that the test hole sealing is in good condition before use • Keep equipment well ventilated
First, it has high temperature control accuracy with a resolution of 0.01°C, enabling precise simulation of set environments. Second, it supports multi-segment programming tests, allowing the setting of complex temperature and humidity change curves. Additionally, it features data interfaces for easy connection to computers to record and print curves, as well as protection functions such as power-off memory, ensuring safe and intelligent operation to meet your diverse testing needs.
Appropriate. The ST-100LD is specifically designed to simulate high-temperature, low-temperature, and humid-heat alternating environments, complying with multiple national military standards and national standards. It utilizes a Panasonic compressor from Japan and PID control, ensuring precise and stable temperature and humidity regulation. This enables effective testing of material or component performance degradation and lifespan under alternating environmental conditions, making it a commonly used equipment for such reliability tests.
For your research scenario that requires rapid temperature changes, the LUGONG ST-100LD is a suitable choice. It performs well in terms of heating and cooling rates. For example, when cooling from 150°C to -70°C, it achieves an average rate of 1°C per minute throughout the process. This is attributed to its efficient dual low-temperature circuit refrigeration system and PID control, which effectively simulates the rapid temperature fluctuations materials undergo during transportation or in extreme climates, allowing for the examination of their performance changes.