Overview
Xinlinte YJ300 high-efficiency oscillator is a device for dispersing and mixing liquid and solid powdery materials. It produces strong collision and shearing effects through high-speed dispersion discs to achieve rapid analysis, uniform mixing and accelerated dissolving of insoluble materials.
Features
1. A large number of samples can be dispersed under the same conditions to improve Test speed and ensure reproducibility and repeatability; 2. The maximum load is 30KG; 3. The equipment moves along the elliptical trajectory according to geometry, the vibration range is 45mm without load, 32mm with full load, the vibration Frequency is about 660 + 40 times/minute adjustable, and the centrifugal force is 20 times the load; 4. The chill down device consists of two low-pressure fans to keep the temperature of the sample container 10 ° C higher than the room temperature, and automatically adjust the fan Power; 5. Completely close the container space to reduce noise and block the bursting of the Glass container or chemical leakage, supplemented by a transparent observation window; 6. Use the German SIEMENS PLC to operate the display system, preset the dispersion time, display the remaining time, total Working time, clamping time and vibration Frequency, all Chinese display; 7. Display the fault code during the operation of the equipment, easy to judge the problem; 8. Easy to operate, automatic clamping, 20 seconds after the chill down fan work, the time reaches the automatic stop.
Principle
The dispersion disc turns two or more liquid and solid powdery materials up and down violently in the container at high speed, resulting in strong collision and shearing, destroying the aggregate, achieving the purpose of rapid analysis and uniform mixing, and accelerating the dissolution of insoluble materials.
Applications
Paints, inks
Steps
1. Place the sample container (glass bottle or plastic bottle) in the suitable sample hole on the sample rack; 2. Close the sealing door; 3. Set the dispersion time and chill down degree; 4. Use automatic clamping to start the dispersion movement; 5. After 20 seconds, the chill down fan starts to work; 6. After the time reaches the preset dispersion time, the equipment automatically stops working.
Notice
• Pay attention to observe the fault code during the operation of the equipment; • Ensure that the sample container is placed correctly; • Set the dispersion time and chill down degree to be adjusted according to actual needs; • Pay attention to the timely processing of samples after the equipment automatically stops.