Overview
DDKSIC CD100 is a Benchtop conductivity and dissolved oxygen meter designed with Keypad Operation. The instrument can measure conductivity, resistivity, TDS, salinity, dissolved oxygen concentration, dissolved oxygen Saturation and temperature and other parameters. It has a high definition resolution LCD custom screen, which is beautiful and clear and easy to operate.
Features
1. Measurement parameters include conductivity, resistivity, TDS, salinity, dissolved oxygen concentration, dissolved oxygen Saturation, ℃.
2. High definition resolution LCD custom screen, beautiful, clear and easy to operate.
3. Intelligent Operating system, support Electrode management, parameter setting and other functions, and provide Measured value stability reminder.
4. Support automatic temperature compensation and Electrode diagnostic function.
5. Electrode constant calibration and solution calibration are supported for conductivity calibration.
6 temperature compensation and pressure compensation automatically, salinity compensation manually.
7. The data storage capacity is 450 sets, including number, value, unit, temperature and time.
8. Support Bluetooth connection to the printer to directly print the results (the printer is optional).
9. Data output methods include U disk and printer.
10. The dustproof and waterproof rating is IP54.
Principle
Electrode measurement conductivity, dissolved oxygen and other parameters are used to ensure measurement accuracy. The Intelligent Operating system processes data, supports Electrode management and parameter setting, and provides reminders when Measured values are stable.
Steps
1. Connect the power supply and turn it on.
2. Measurement parameters (such as conductivity, dissolved oxygen, etc.) are selected as needed.
3. Electrode calibration (support Electrode constant calibration or solution calibration).
4. Set compensation parameters (temperature compensation automatic, salinity compensation manual).
5. Start measurement, the instrument automatically displays the stable value and reminds.
6. Store or output data (via USB flash drive or Bluetooth printer).
Notice
Make sure the power supply is DC120V to avoid voltage mismatches.
- Pay attention to dustproof and waterproof during operation, meeting the IP54 level requirements.
- Use standard solutions when calibrating Electrodes to ensure accuracy.
- Salinity compensation needs to be set manually, be careful to enter the correct value.
- Data storage and output check if the connected device is normal.
Electrode diagnosis and maintenance are performed regularly.