$ 911.00Ex works
Can simultaneously detect 4 kinds of gases, integrated temperature Humidity detection, support diffusion and pump sampling, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, Operating temperature -40~ 55 ℃.
Category : Gas Detector
Brand : Empaer
SKU : NB049494
Service :The delivery and service By NBCLab.Com
The Pathfinder series fixed carbon dioxide detector is a high-performance and fully functional mid-to-high-end on-site gas monitoring instrument of the Empaer brand, which supports the simultaneous detection of up to 4 kinds of gases and temperature Humidity. The products are divided into general-purpose and special-purpose models. The special models are customized according to customer application scenarios, which is more professional and reliable. Its main function is to convert the detected gas concentration and temperature Humidity into standard signals and transmit them to PLC, DCS, alarm control host and other host computers to form an intelligent Gas detection Alarm Control system. The built-in relay can control peripheral equipment such as sound and light alarms, fans, solenoid valves, and supports remote monitoring, alarm value setting and calibration.
1. Support diffusion and pump-suction Sampling method, maximum simultaneous detection of 4 gas types, integrated temperature Humidity detection. 2. Internet of Things function, can be connected to Empaer server to realize mobile phone and computer remote monitoring, alarm reminder, alarm value setting, etc., support NB-IoT, 4G or WIFI networking for remote parameter configuration and program upgrade. 3. The shell uses self-designed molds, non-public molds, with strong professionalism and high brand recognition. 4. High Standard High Performance, Reference to Various Industry Standards, Wide Application, Good Stability. 5. Ultra-high definition 2.0-inch color display with a viewing distance of 10 meters. 6. Complete certification, including dual explosion-proof certification, CPA certification, SIL2 certification, CE certification, CNAS metrology authentication. 7. Support a variety of wireless communication options, such as GPRS, LORA, WIFI, ZIGBEE, NB-IoT, 4G, 5G. 8. Double temperature Humidity design, physical + software double revisit Humidity compensation, real-time detection and display transmission. 9. Bilingual Operating system, supports Chinese and English switching. 10. Support a variety of Installation methods, such as Wall-Mounted, Rod, Ceiling, Pipeline. 11. Black box storage function, recording operation, alarm, over-temperature, over-range use. 12. Reminder and alarm functions are complete, including Sensor expiration, super concentration, super temperature, super Humidity, fault, instrument calibration reminder, etc. 13. Operating interface has a guide function to prevent misoperation. 14. Zero automatic correction function. 15. Waterproof, dustproof, anti-static, anti-electromagnetic interference, special anti-cross gas interference.
The Pathfinder series fixed Gas detector detects the gas concentration and temperature Humidity on site, converts it into standard signals (such as 4-20mA, RS-485, etc.), and transmits it to the PLC, DCS, alarm control host and other host computers for unified display, management and control, so as to build an intelligent Gas detection alarm system. Built-in relays can control external devices, such as sound and light alarms, fans, solenoid valves. Through the Internet of Things function, connect the Empaer server to realize remote monitoring, alarm value setting and calibration.
Petroleum and petrochemical, mining, gas, aerospace and military, chemical industry, electric power, scientific research institutes, municipal engineering, metallurgy
Measurement equipment CPA, CCCF, Flameproof, Intrinsic Safety (IS), IP66 protection, Mine safety, Coal safety, ROSH, SIL2, CE, ATEX, IEC
1. Installation equipment: Select Wall-Mounted, Rod, Ceiling or Pipeline Installation method. 2. Connect power supply: use 12~ 36VDC power supply, typically 24VDC, optional external battery. 3. Configure signal output: Select wired output such as 4-20mA, RS-485 or wireless output such as WIFI, 4G. 4. Set parameters: Configure parameters through infrared remote control or remote IoT, including alarm values, server ports, etc. 5. Start detection: The equipment automatically starts gas concentration and temperature Humidity detection. 6. Monitoring and alarming: Monitor data through the display screen or remote device, and trigger an alarm when the device exceeds the limit. 7. Maintenance and calibration: Calibration is carried out regularly (recommended cycle is 1 year), and remote calibration and program upgrades are supported.
• Ensure that the Ambient Temperature is between -40 and 55 ° C during installation, Humidity 10% -95% RH without condensation. • Avoid use in environments beyond 86-106KPA Operating Pressure. • Regularly check the life of the Sensor. The life of the Sensor is determined by the testing principle. Miscellaneous components are recommended to have a service life of ≥ 5 years. • When using infrared remote control or remote IoT operation, pay attention to prevent misoperation and follow the Operating interface guidelines. • When used in explosion-proof environments, ensure compliance with Explosion-proof level Exd II C T6 and EX TD A21 requirements. • When configuring and upgrading remotely, ensure a stable network connection, such as using NB-IoT, 4G or WIFI. The calibration period is recommended to be 1 year, and pay attention to environmental conditions when using the automatic calibration function. • Device power consumption < 2W, depending on the Sensor, consult customer service for details.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.