$ 265.00Ex works
With explosion-proof IP66 Protection Rating, Operating temperature range -40~ 55 ℃. Support remote configuration and OTA upgrade, built-in intermittent detection protection function, provide a variety of Installation methods to adapt to different scene needs.
Category : Gas Detector
Brand : Empaer
SKU : NB049502
Service :The delivery and service By NBCLab.Com
Empaer Volkswagen series stationary hydrogen sulfide detector (model APEG-D-H2S) is a cost-effective and high-performance on-site gas monitoring instrument. It is divided into general-purpose and special-purpose models. The special-purpose models can be customized according to customer application scenarios. The equipment converts the detected gas concentration into standard signals and transmits them to upper computers such as PLC and DCS. The built-in relay can control sound and light alarms, fans and other peripheral equipment. It supports remote monitoring, alarm value setting and calibration functions. It is suitable for petroleum and petrochemical, gas, chemical, electric power and other industries.
1. Settling 10 years of star products, Internet of Things products, Explosion-proof level Exd II C T6, EX TD A21, Protection Rating IP66. 2. Appearance design with independent intellectual property rights, high brand recognition. 3. High performance, in line with a variety of industry standards, widely used and stable. 4. Ultra high definition color display, viewing distance ≥ 10 meters. 5. A variety of wired and wireless communication output methods, supporting NB-IoT, 4G, WIFI, etc. 6. Chinese and English bilingual Operating system. 7. Remote control function, support parameter configuration and program upgrade. 8. Protection functions include intermittent detection and Sensor automatic protection (optional). 9. The black box function records operation, alarm, over-temperature, and over-range use. 10. Complete reminder and alarm functions, such as Sensor expiration, super concentration, failure, etc. 11. Humanized operation guidelines to prevent misoperation. 12. Zero automatic correction function. 13. Operation mode: button and infrared remote control. 14. Easy to install, support Wall-Mounted, ceiling type, pipeline type, etc. 15. Waterproof, dustproof, anti-static, anti-electromagnetic interference, special anti-cross gas interference.
The detector detects the concentration of hydrogen sulfide gas on site by diffusion type (default) or Miscellaneous Sampling method, converts the concentration into a standard signal (such as 4-20mA, RS-485, etc.), and transmits it to PLC, DCS or alarm control host for unified display and management. Built-in relays can control sound and light alarms, fans and other equipment in conjunction to realize intelligent Gas detection and alarm control.
Petroleum and petrochemical, gas, aerospace and military industry, chemical industry, electric power, scientific research institutes, municipal engineering, mining, metallurgy
Measurement equipment CPA, CCCF, Flameproof, Intrinsic Safety (IS), IP66 protection, Mine safety, Coal safety, ROSH, SIL2, CE, ATEX, IEC
1. Select the Installation method (e.g. Wall-Mounted, Pipeline) and install it. 2. Connect the power supply (12~ 36VDC typical power supply) and the signal output line. 3. Set parameters such as language and alarm value through button or infrared remote control operation. 4. For remote functions, configure NB-IoT, 4G or WIFI networking. 5. Start the equipment for Gas detection, monitor the display and alarm status. 6. Periodic calibration (recommended cycle of 1 year).
* Ensure Ambient Temperature between -40~ 55 ℃ and Humidity 10% -95% RH without condensation during installation. Avoid use at operating pressure 86-106KPA or at extreme storage temperatures (-10-30 ° C). * Confirm Sensor type and range before use, and contact mall customer service for specific parameters. * Pay attention to cyber security when remote control to prevent unauthorized access. Regularly check the Protection Rating and explosion-proof performance to ensure that the equipment is in good condition. * Follow humanized guidelines during operation to prevent malfunctions caused by misoperation. * Use original parts for calibration and maintenance to maintain accuracy and longevity.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.