$ 370.00Ex works
With explosion-proof IP66 Protection Rating, Response Time T90 conforms to the national standard, supports a variety of communication output and remote paraMeter configuration, can automatically correct zero points and record operation alarm history, adapt to -40~ 55 ℃ working environment.
Category : Gas Detector
Brand : Empaer
SKU : NB049506
Service :The delivery and service By NBCLab.Com
Empaer Volkswagen Series Fixed Chlorine Detector APEG-D-CL2 is a cost-effective, high-performance and fully functional on-site gas monitoring instrument. The device converts the detected chlorine concentration into a standard signal and transmits it to the PLC, DCS and other host computers. The built-in relay can control sound and light alarms, fans and other peripheral equipment. It supports remote monitoring, alarm value setting and calibration functions. It is suitable for petroleum and petrochemical, gas, chemical, electric power and other industries.
1. Appearance design with independent intellectual property rights, high brand recognition 2. High performance, in line with a variety of industry standards, widely used and stable 3. Ultra high definition color display, viewing distance up to 10 meters 4. A variety of wired and wireless communication output methods to meet system docking requirements 5. Bilingual Operating system 6. Support NB-IoT, 4G or WIFI remote parameter configuration and program upgrade 7. Intermittent Detection and Sensor Automatic Protection Function (Optional) 8. Black box function, recording operation, alarm, over-temperature and over-range use 9. Complete reminder and alarm functions, including Sensor expiration, over-concentration, over-temperature, fault, etc 10. Humanized operation guidelines to prevent misoperation 11. Zero automatic correction function 12. Operation mode of button and remote control 13. Easy installation, support Wall-Mounted, ceiling type, pipeline type, etc 14. Waterproof, dustproof, anti-static, anti-electromagnetic interference, special anti-cross gas interference
The detector detects the on-site chlorine concentration by diffusion (default) or Miscellaneous Sampling method, converts it into standard signals (such as 4-20mA, RS-485, etc.), and transmits it to PLC, DCS and other host computers for display and management. Built-in relays can control peripheral devices to realize alarm and control functions.
Petroleum and petrochemical, gas, aerospace and military industry, chemical industry, electric power, scientific research institutes, municipal engineering, mining, metallurgy
Measurement equipment CPA, CCCF, Flameproof, Intrinsic Safety (IS), IP66 protection, Mine safety, Coal safety, ROSH, SIL2, CE, ATEX, IEC
1. Install the equipment, select Wall-Mounted, Ceiling or Pipeline Installation method 2. Connect power supply (12~ 36VDC typical power supply) and signal output line 3. Initial setting by pressing buttons or infrared remote control, including language selection (Chinese/English) and alarm value configuration 4. If you need remote functions, perform parameter settings and program upgrades through NB-IoT, 4G or WIFI networking 5. Periodic calibration (recommended period of 1 year), using the automatic calibration function 6. Monitor the display and alarm output to ensure the normal operation of the equipment
• Ensure Ambient Temperature between -40~ 55 ℃ during installation, Humidity 10% -95% RH without condensation • Avoid use at operating pressure 86-106KPA or extreme storage temperatures (-10-30 ° C) • Regularly check Sensor life and attenuation performance, contact customer service specifically • Parameters will not be lost during remote upgrades, but it is still recommended to back up important settings • Optional functions such as Sensor Protection, Wireless Output, etc. need to be confirmed in advance Explosion-proof level of Exd II C T6 and EX TD A21, to be used in a suitable environment • Power consumption is less than 2W, but according to Sensor, contact customer service for details
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.