$ 254.00Ex works
Pump sampling ensures fast detection speed, can store 100000 data, support buzzer and LED dual alarm. Explosion-proof level EXia II CT6, Battery capacity 2800mAh, working life 10-60 hours.
Category : Gas Detector
Brand : Empaer
SKU : NB049523
Service :The delivery and service By NBCLab.Com
Lightning series Handheld gas detector is an Empaer brand AASD-EX model product, which has been on the market for 10 years. It has been verified by various application scenarios and has the characteristics of stable performance, superior functions, simple operation and fast detection. The instrument collects on-site gas into the core sensor device through the pump suction Sampling method to detect concentration, supports Data storage, analysis and connection to printer printing. Widely used in gas, metallurgy, petroleum and petrochemical, aerospace and military, chemical industry, electric power, scientific research institutes, municipal engineering and other industries.
1. National patented product, utility model patent number is 201320023174.0 2. Adopt pump suction collection method to ensure airflow and air pressure Stability, improve detection speed and accuracy 3. National Intrinsic Safety (IS) certification standards, circuits are designed according to intrinsic safety requirements, and the certification certificate is EXia II CT6 4. Refer to a variety of industry standards at home and abroad, Application is extensive, stable performance 5. Color high definition display, display detection data, alarm information, time and other information 6. Fool-like operation, simple and convenient design, can be used without reading the manual 7. Advanced Filtering Technology for High Accuracy Detection 8. High-capacity storage, capable of storing 100,000 pieces of data, and supports multiple storage intervals 9. Battery capacity 2800mAh, electrochemistry principle works continuously for more than 22 hours, catalytic combustion principle for more than 10 hours 10. Double alarm of buzzer and LED light, alarm value can be set by yourself, with high and low levels 11. Intelligent design, the system has self-diagnosis function, automatic alarm battery low, Sensor failure, etc
Lightning Series Handheld Gas Detectors detect gas concentration by pumping and sampling field gas into the core sensor device inside the device. This process ensures the Stability of airflow and pressure in the air chamber, thus improving detection speed and accuracy. The detected concentration data can be stored and analyzed, and supports connected printer printing.
Gas, metallurgy, petroleum and petrochemical, aerospace and military industry, chemical industry, electric power, scientific research institutes, municipal engineering
Measurement Appliances CPA, Intrinsic Safety (IS), IP65 Protection, ROSH, CE
1. Handheld or neck hanging instrument to ensure that it is in the working environment 2. Start the device by pressing the button, no complicated settings are required 3. The instrument automatically performs pump sampling to detect gas concentration 4. Check the detection data, alarm information, etc. on the color display screen 5. Set the alarm value as needed, and the instrument will alarm through the buzzer and LED lights 6. Data is automatically stored, and the storage interval can be selected 7. Connect a computer for data printing and analysis
* Recommended calibration period is 1 year to ensure detection accuracy * When the battery is low, the device will automatically alarm and need to be charged in time. * Sensor life or failure of the device will alarm, need to contact the manufacturer to deal with * Working ambient temperature range is -40~ 55 ℃, Humidity 0% -95% RH (no condensation) * Avoid use in environments beyond 80-120KPA Operating Pressure * The instrument has the ability to resist electromagnetic interference and cross-gas interference, but pay attention to environmental conditions Storage temperature is recommended to be -10~ 30 ° C to extend service life
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.