Maximum support for simultaneous detection of 4 kinds of gases, integrated temperature and Humidity detection function, with Internet of Things remote monitoring capability, Response Time T90 ≤ national standard, Protection Rating up to IP66, adapt to a variety of Installation methods.
Category : Gas Detector
Brand : Empaer
SKU : NB049612
Service :The delivery and service By NBCLab.Com
The Pathfinder series stationary hydrogen detector (sound and light alarm) is a high-performance, fully functional mid-range on-site gas monitoring instrument under the Empaer brand, model AATL-H2. It supports the simultaneous detection of up to 4 gases and integrates temperature Humidity detection, compatible with diffusion and pump suction Sampling methods. The product can convert the detected gas concentration and temperature Humidity into standard signals and transmit them to the host computer. The built-in relay can control peripheral devices such as sound and light alarms, and supports IoT functions for remote monitoring and setting.
1. Supports simultaneous detection of 4 gases, integrated temperature and Humidity detection, compatible with diffusion and pump Sampling methods 2. Internet of Things functions, which can be remotely monitored through NB-IoT, 4G or WIFI, alarm settings and program upgrades 3. Independent design of shell molds, high brand recognition 4. Ultra high definition 2.0 inch color display, viewing distance of 10 meters 5. Complete certification, including dual explosion-proof certification, CPA certification, SIL2 certification, CE certification, CNAS metrology authentication 6. Support a variety of wireless communication options, such as GPRS, LORA, WIFI, ZIGBEE, NB-IoT, 4G, 5G 7. Double Temperature Humidity Design, Physical + Software Double Compensation 8. Bilingual Operating system 9. Installation methods for multiple application scenarios, such as Wall-Mounted, pole, ceiling, pipeline 10. Black box storage function, recording operation, alarm, over-temperature and over-range use 11. Multiple reminder and alarm functions, including Sensor expiration, over concentration, over temperature, over Humidity, fault, calibration reminder 12. Operating interface has a guide function to prevent misoperation 13. Zero automatic correction function 14. Waterproof, dustproof, anti-static, anti-electromagnetic interference, special anti-cross gas interference
The detector detects the hydrogen concentration and temperature Humidity on site through diffusion or pumping sampling, and converts it into standard signals (such as 4-20mA, RS-485, etc.), which are transmitted to the host computer such as PLC, DCS or alarm control host for unified display and management. Built-in relays can control sound and light alarms, fans and other peripheral equipment to realize Gas detection and alarm Control system.
Petroleum and petrochemical, mining, gas, aerospace and military, chemical industry, electric power, scientific research institutes, municipal engineering, metallurgy
Measurement equipment CPA, CCCF, explosion-proof, Intrinsic Safety (IS), IP66 protection, mine safety, coal safety, ROSH, SIL2, CE, ATEX, IEC
1. Install the equipment, select Wall-Mounted, Rod, Ceiling or Pipeline Installation method 2. Connect the power supply, the typical power supply is 24VDC 3. Set parameters such as alarm values and server ports through infrared remote control or remote IoT 4. Start detection, the instrument automatically monitors gas concentration and temperature Humidity 5. Remote parameter configuration and program upgrade through NB-IoT, 4G or WIFI 6. Calibration is carried out regularly, with a recommended cycle of 1 year
* Installation Ensure Ambient Temperature in the range of -40~ 55 ℃, Humidity 10% -95% RH No condensation * Check the power supply before use to avoid overvoltage operation * Periodic calibration to maintain detection accuracy, recommended once a year * Avoid use in strong electromagnetic interference environment to ensure anti-interference performance * Follow the interface guidelines when operating to prevent misoperation Storage temperature is controlled at -10~ 30 ° C to avoid extreme conditions * If you need to detect multiple gases at the same time, consult customer service to confirm compatibility * When selecting wireless communication function, choose GPRS, LORA, WIFI, etc. according to your needs * Pay attention to the Protection Rating IP66 to ensure waterproof and dustproof, but avoid long-term exposure to harsh environments
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.