$ 743.00Ex works
Supports simultaneous detection of 4 gases and integrated temperature Humidity monitoring, compatible with pumping and diffusion Sampling method, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Operating temperature range -40~ 55 ℃.
Category : Gas Detector
Brand : Empaer
SKU : NB049620
Service :The delivery and service By NBCLab.Com
The Pathfinder series stationary oxygen detector (pump suction) is a high-performance on-site gas monitoring instrument of the Empaer brand AATL-O2 model. It supports two Sampling methods of pump suction and diffusion, detects up to 4 gases simultaneously and integrates temperature Humidity detection. The instrument converts the detected gas concentration and temperature Humidity into standard signals and transmits them to the host computer. The built-in relay can control peripheral devices, and can realize remote monitoring, alarm setting and calibration functions by connecting to the Empaer server.
1. Support diffusion and pump-suction Sampling method, maximum simultaneous detection of 4 gas types, integrated temperature and Humidity detection 2. Internet of Things function: support NB-IoT, 4G or WIFI networking, realize remote monitoring, alarm reminder and parameter configuration 3. Independent design of shell molds, high brand recognition 4. High standards and high performance, with reference to a variety of industry standards at home and abroad 5. Ultra high definition 2.0 inch color display, visual distance ≥ 10 meters 6. Complete certification: double explosion-proof certification, CPA certification, SIL2 certification, CE certification, CNAS metrology authentication 7. Support a variety of wireless communication options: GPRS, LORA, WIFI, ZIGBEE, NB-IoT, 4G, 5G 8. Double Temperature Humidity Design, Physical + Software Double Compensation 9. Bilingual Operating system 10. Installation method for multiple application scenarios: Wall-Mounted, pole type, ceiling type, pipeline type 11. Black box storage function: operation record, alarm record, over-temperature and over-range record 12. Complete reminder and alarm functions: Sensor expiration, super concentration, super temperature, super Humidity, fault, calibration reminder 13. Operating interface guide function to prevent misoperation 14. Zero automatic correction function 15. Waterproof, dustproof, anti-static, anti-electromagnetic interference, special anti-cross gas interference
The instrument detects the oxygen concentration and temperature Humidity on site by sampling by pump suction or diffusion, and converts the detection data into standard signals (such as 4-20mA, RS-485, etc.) and transmits them to the upper computer such as PLC, DCS or alarm control host. The built-in relay can control the sound and light alarm, fan, solenoid valve and other peripheral equipment to realize the intelligent management of the Gas detection Alarm Control system.
Petroleum and petrochemical, mining, gas, aerospace and military, chemical industry, electric power, scientific research institutes, municipal engineering, metallurgy
Measurement equipment CPA, CCCF, Flameproof, Intrinsic Safety (IS), IP66 protection, Mine safety, Coal safety, ROSH, SIL2, CE, ATEX, IEC
1. Select Installation method: Wall-Mounted, Rod, Ceiling or Pipeline 2. Connection power supply: 12~ 36VDC typical power supply 24VDC, optional external battery 3. Sampling method: diffusion, flow, pipeline or pump suction 4. Set the signal output: select 3-wire system 4-20mA, RS-485, voltage output, etc 5. Networking configuration: remote parameter setting through NB-IoT, 4G or WIFI connection to the server 6. Alarm settings: Configure concentration, temperature, Humidity Alarm threshold 7. Regular calibration: It is recommended that the calibration period be 1 year, and remote calibration is supported
• Working ambient temperature range is -40~ 55 ℃, storage temperature is -10~ 30 ℃ • Operating Pressure must be kept within the range of 86-106KPA • Environmental humidity of 10% -95% RH to avoid condensation • Protection Rating is IP66 to ensure waterproof and dustproof Explosion-proof level Exd II C T6 and EX TD A21 for use in an explosion-proof environment • Power consumption < 2W, depending on Sensor • The maximum length of the split body supports 100 meters, please consult customer service for details. • Wireless communication function is optional and needs to be configured according to requirements The calibration period is recommended to be 1 year, and the automatic correction function is supported • Pay attention to the interface size when installing, the default inner screw M20 * 1.5
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.