$ 388.00Ex works
It can simultaneously detect 4 kinds of gases and integrate temperature and humidity monitoring, support diffusion and pump sampling methods, with a 10-Meter visual distance high definition color screen, realize remote monitoring and paraMeter configuration through the Internet of Things, and adapt to the working environment of -40~ 55 ℃.
Category : Gas Detector
Brand : Empaer
SKU : NB049633
Service :The delivery and service By NBCLab.Com
Pathfinder Series Fixed Combustible Gas Detector (4G) is a high-performance, fully functional mid-to-high-end on-site gas monitoring instrument that supports the simultaneous detection of 4 gases and comes with its own temperature and humidity detection. The products are divided into general-purpose and special-purpose models. The special models are customized according to customer application scenarios, which is more professional and reliable. The main function is to convert the detected gas concentration and temperature and humidity into standard signals, which are transmitted to PLC, DCS and other host computers for unified management. The built-in relay can control peripheral devices such as sound and light alarms. Connection to Empaer server can realize remote monitoring, alarm setting and calibration.
1. Support diffusion and pump sampling methods, maximum simultaneous detection of 4 gases, integrated temperature and humidity detection. 2. Internet of Things function, supporting NB-IoT, 4G or WIFI networking, enabling remote monitoring, alarm reminders and parameter configuration. 3. Independent design of shell molds, with high brand recognition. 4. High standard and high performance, with reference to a variety of industry standards, widely used and stable. 5. Ultra high definition 2.0 inch color display, visual distance ≥ 10 meters. 6. Complete certification, including dual explosion-proof certification, CPA certification, SIL2 certification, CE certification, CNAS metrology authentication. 7. Support a variety of wireless communications, such as GPRS, LORA, WIFI, ZIGBEE, NB-IoT, 4G, 5G (optional). 8. Dual temperature and humidity design, physical + software double compensation, real-time detection and display. 9. Chinese and English bilingual operating system. 10. Support Wall-Mounted, rod, ceiling, pipeline and other installation methods. 11. Black box storage function, recording operation, alarm, over-temperature, over-range, etc. 12. Multiple reminder and alarm functions, including Sensor expiration, over concentration, over temperature, over humidity, fault, calibration reminder. 13. The operation interface has a guide function to prevent misoperation. 14. Zero automatic correction function. 15. Waterproof, dustproof, anti-static, anti-electromagnetic interference, special anti-cross gas interference.
The Pathfinder series fixed Gas detector detects the gas concentration and temperature and humidity on site, converts it into standard signals (such as 4-20mA, RS-485, etc.), and transmits it to the PLC, DCS, alarm control host and other host computers for unified display, management and control. Built-in relays can control peripheral devices such as sound and light alarms, fans, and solenoid valves. After connecting to the Empaer server, it supports remote monitoring, alarm value setting and calibration, and realizes an intelligent Gas detection alarm control system.
Petroleum and petrochemical, mining, gas, aerospace and military, chemical industry, electric power, scientific research institutes, municipal engineering, metallurgy
Measurement equipment CPA, CCCF, Flameproof, Intrinsic Safety (IS), IP66 protection, Mine safety, Coal safety, ROSH, SIL2, CE, ATEX, IEC
1. To install the equipment, choose Wall-Mounted, rod, ceiling or pipeline installation methods. 2. Connect the power supply, the power supply mode is 12~ 36VDC (typical 24VDC), and an external battery is optional. 3. Configure sampling methods, such as diffusion, flow, pipeline or pump suction. 4. Set parameters through infrared remote control or remote IoT, including alarm values, server ports, etc. 5. Connect the host computer and output the signal to PLC, DCS and other equipment. 6. Remote monitoring, remote setting and upgrade through NB-IoT, 4G or WIFI networking. 7. Regular calibration, the recommended period is 1 year, and remote calibration is supported.
• Make sure the Ambient Temperature is in the range of -40~ 55 ℃ during installation to avoid condensation. • The power supply voltage needs to be between 12 and 36VDC, with a typical value of 24VDC. • The selection of sampling method needs to consult customer service according to specific application scenarios. • When remote networking, ensure network stability and avoid parameter configuration errors. • Regularly check Sensors and Calibration to ensure detection accuracy. • Avoid use in over-temperature, over-humidity or over-pressure environments, Operating Pressure is 86-106KPA. • When using infrared remote control operation, pay attention to prevent interference. Storage temperature should be maintained at -10 to 30 degrees Celsius to avoid extreme conditions. • The special model has anti-cross gas interference, and the general model needs to pay attention to gas interference.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.