$ 410.00Ex works
It can simultaneously detect four gases and integrate temperature and humidity monitoring, using dual temperature and humidity compensation technology, with a 10-Meter visual distance color screen, and supports a variety of wireless communication and remote configuration functions.
Category : Gas Detector
Brand : Empaer
SKU : NB049634
Service :The delivery and service By NBCLab.Com
Pathfinder series stationary hydrogen sulfide detector (4G) is a high-performance, fully functional mid-to-high-end on-site gas monitoring instrument of Empaer brand. It supports the detection of up to 4 gases at the same time and integrates temperature and humidity detection. The products are divided into general-purpose and special-purpose models. The special-purpose models are customized design, which is more professional and reliable. The main function is to convert the detected gas concentration and temperature and humidity into standard signals, which are transmitted to PLC, DCS and other host computers for unified management. The built-in relay can control sound and light alarms and other peripheral equipment. It supports remote monitoring, alarm setting and calibration of the Internet of Things. It is suitable for petroleum and petrochemical, mining, gas, aerospace and military, chemical industry, electric power, scientific research institutes, municipal engineering, metallurgy and other industries.
1. Support diffusion and pump sampling methods, up to 4 kinds of gases are detected simultaneously, with temperature and humidity detection 2. Internet of Things function: Connect the Empaer server to realize remote monitoring of mobile phones and computers, alarm reminders, alarm value settings, etc., support NB-IoT, 4G or WIFI networking remote parameter configuration and program upgrade 3. The shell adopts self-designed molds, non-public molds, with strong professionalism and high brand recognition 4. High standard and high performance, refer to a variety of industry standards, widely used, good stability 5. Ultra high definition 2.0 inch color display, viewing distance of 10 meters 6. Complete certification: double explosion-proof certification, CPA certification, SIL2 certification, CE certification, CNAS metrology authentication 7. Support a variety of wireless communications: GPRS, LORA, WIFI, ZIGBEE, NB-IoT, 4G, 5G (optional) 8. Dual temperature and humidity design, physical + software dual temperature and humidity compensation, real-time detection and display transmission 9. Bilingual operating system: switch between Chinese and English 10. Multi-application scenario installation method: Wall-Mounted, rod type, ceiling type, pipeline type, etc 11. Black box storage function: operation record, alarm record, over-temperature use record, over-range use record 12. Reminder and alarm functions are complete: Sensor expiration reminder, super concentration alarm, super temperature alarm, super humidity alarm, fault alarm, instrument calibration reminder, etc 13. Operation interface guidance function: user-friendly design to prevent misoperation 14. Zero automatic correction function 15. Waterproof, dustproof, anti-static, anti-electromagnetic interference, special anti-cross gas interference
The detector detects the gas concentration and temperature and humidity on site through the Sensor, converts the detected data into standard signals (such as 4-20mA, RS-485, etc.), and transmits it to the PLC, DCS, alarm control host and other host computers for unified display, management and control. Built-in relays can control peripheral devices such as sound and light alarms, fans, solenoid valves. Connect the Empaer server through the Internet of Things to realize remote monitoring, alarm value setting and calibration functions.
Petroleum and petrochemical, mining, gas, aerospace and military, chemical industry, electric power, scientific research institutes, municipal engineering, metallurgy
Measurement equipment CPA, CCCF, Flameproof, Intrinsic Safety (IS), IP66 protection, Mine safety, Coal safety, ROSH, SIL2, CE, ATEX, IEC
1. Installation equipment: choose Wall-Mounted, rod, ceiling or pipeline installation method 2. Connect power supply: use 12~ 36VDC power supply (typical 24VDC), optional external battery 3. Sampling settings: choose diffusion, flow, pipeline or pump sampling according to needs 4. signal output: configure wired signal (such as 4-20mA, RS-485) or wireless signal (such as WIFI, 4G) 5. Parameter configuration: set alarm values, server ports, etc. through infrared remote control or remote IoT 6. Remote monitoring: Connect to the Empaer server to realize remote monitoring and control of mobile phones or computers 7. Calibration and maintenance: regular calibration (recommended period of 1 year), using automatic calibration function
* Ambient Temperature in the range of -40~ 55 ℃, humidity 10% -95% RH (no condensation) * Avoid use outside the overpressure (86-106KPA) range to prevent equipment damage * Regularly check the life of the Sensor, the recommended calibration period is 1 year to ensure detection accuracy * When using infrared remote control or remote operation, follow the interface guidelines to prevent misoperation * In flammable and explosive environments, ensure that the explosion protection level meets the requirements (such as Exd II C T6) * Pay attention to the Protection Rating IP66 to avoid water and dust entering the equipment * When upgrading remotely, ensure that the network connection is stable and avoid interruptions leading to program errors
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.