$ 1014.00Ex works
Maximum support for simultaneous detection of 4 gases, integrated temperature and humidity detection, support for diffusion and pump sampling, remote paraMeter configuration and program upgrade functions, Response Time T90 ≤ national standard, Protection Rating IP66.
Category : Gas Detector
Brand : Empaer
SKU : NB049637
Service :The delivery and service By NBCLab.Com
Pathfinder Series Fixed Carbon Dioxide Detector (4G) is a high-performance and fully functional mid-to-high-end on-site gas monitoring instrument launched by Empaer brand. It supports the simultaneous detection of 4 gases and comes with its own temperature and humidity detection. The product is divided into general-purpose and special-purpose models. The special-purpose models are customized according to customer application scenarios, which is more professional and reliable. Its main function is to convert the detected gas concentration and temperature and humidity into standard signals, which are transmitted to PLC, DCS and other host computers for unified management, and built-in relays control peripheral devices such as sound and light alarms, fans, etc. By connecting to the Empaer server, functions such as remote monitoring, alarm value setting and calibration can be realized.
1. Support diffusion and pump sampling methods, maximum simultaneous detection of 4 gas types, integrated temperature and humidity detection 2. Internet of Things function: remote monitoring, alarm reminder, parameter configuration and program upgrade through NB-IoT, 4G or WIFI networking 3. Independent design of shell molds, high brand recognition 4. High standard and high performance, with reference to a variety of industry standards, widely used and stable 5. Ultra high definition 2.0 inch color display, viewing distance of 10 meters 6. Complete certification: double explosion-proof certification, CPA certification, SIL2 certification, CE certification, CNAS metrology authentication 7. Support a variety of wireless communications: GPRS, LORA, WIFI, ZIGBEE, NB-IoT, 4G, 5G (optional) 8. Dual temperature and humidity design, physical + software dual compensation, real-time detection and display 9. Chinese and English bilingual operating system 10. Multi-application scenario installation method: Wall-Mounted, rod type, ceiling type, pipeline type, etc 11. Black box storage function: operation record, alarm record, over-temperature use record, over-range use record 12. Complete reminder and alarm functions: Sensor expiration, super concentration, super temperature, super humidity, fault, instrument calibration, etc 13. Operation interface guide function to prevent misoperation 14. Zero automatic correction function 15. Waterproof, dustproof, anti-static, anti-electromagnetic interference, special anti-cross gas interference
The Pathfinder series fixed carbon dioxide detector detects the gas concentration and temperature and humidity on site through the Sensor, converts the detected data into standard signals (such as 4-20mA, RS-485, etc.), and then transmits it to the PLC, DCS, alarm control host and other host computers for unified display, management and control. Built-in relays can control peripheral devices such as sound and light alarms, fans, solenoid valves. Through the Internet of Things function, the device can be connected to the Empaer server to realize remote monitoring, alarm value setting and calibration.
Petroleum and petrochemical, mining, gas, aerospace and military, chemical industry, electric power, scientific research institutes, municipal engineering, metallurgy
Measurement equipment CPA, CCCF, Flameproof, Intrinsic Safety (IS), IP66 protection, Mine safety, Coal safety, ROSH, SIL2, CE, ATEX, IEC
1. Installation equipment: choose Wall-Mounted, rod, ceiling or pipeline installation method 2. Connect power supply: use 12~ 36VDC power supply (typical 24VDC), optional external battery 3. Configure signal output: select wired signal (such as 4-20mA, RS-485) or wireless signal (such as WIFI, 4G) 4. Set parameters: configure alarm values, server ports, etc. through infrared remote control or remote IoT 5. Start detection: The device starts to detect gas concentration and temperature and humidity, and transmits data to the host computer 6. Remote monitoring: Realize remote monitoring and setting of mobile phones or computers through Empaer servers 7. Regular Maintenance: It is recommended to calibrate once a year to check the Sensor and function
* Ambient Temperature in the range of -40~ 55 ℃, humidity 10% -95% RH no condensation * Avoid use at operating pressure 86-106KPA or extreme storage temperatures (-10-30 ° C) * Pay attention to gas flow when using diffusion sampling, and choose pump suction to improve detection efficiency * Regularly check Sensor life, it is recommended to calibrate annually to ensure accuracy * Ensure stable network connection during remote configuration to prevent parameter setting failure * Follow the interface guidelines during operation to avoid equipment failure due to misoperation * When used in flammable and explosive environments, ensure that the explosion-proof level meets the requirements * When installing separately, the distance between the watch head and the Probe should not exceed 100 meters. Please consult customer service for details. When selecting wireless communication function, choose the appropriate module according to the site requirements * Pay attention to power consumption control, generally less than 2W, depending on the Sensor
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.