$ 512.00Ex works
Maximum support for simultaneous detection of 4 gases, integrated temperature and humidity detection and double compensation, using high definition 2.0-inch color display, visual distance of 10 Meters, with a variety of wireless communication methods and installation methods.
Category : Gas Detector
Brand : Empaer
SKU : NB049638
Service :The delivery and service By NBCLab.Com
Pathfinder Series Fixed Chlorine Detector (4G) is a high-performance and fully functional mid-to-high-end on-site gas monitoring instrument launched by Empaer brand. It supports the detection of up to 4 gases at the same time and has its own temperature and humidity detection. The instrument is divided into general-purpose and special-purpose models. The special models are customized according to customer application scenarios, which is more professional and reliable. Its main function is to convert the detected gas concentration and temperature and humidity into standard signals, which are transmitted to PLC, DCS and other host computers for unified management. The built-in relay can control peripheral devices such as sound and light alarms, fans, etc., and can be connected to the Empaer server for remote monitoring, alarm setting and calibration. Products are suitable for petroleum and petrochemical, mining, gas, aerospace and military, chemical, electric power, research institutes, municipal engineering, metallurgy and other industries.
1. Support diffusion and pump sampling methods, maximum simultaneous detection of 4 gas types, integrated temperature and humidity detection 2. Internet of Things function: It can be connected to the Empaer server to realize remote monitoring, alarm reminder and alarm value setting of mobile phones and computers, and supports NB-IoT, 4G or WIFI networking for remote parameter configuration and program upgrade 3. The shell uses self-designed molds, non-public molds, strong professionalism, and high brand recognition 4. Reference to a variety of industry standards at home and abroad, wide application fields, high stability 5. Ultra high definition 2.0 inch color display, viewing distance of 10 meters 6. Complete certification: double explosion-proof certification, CPA certification, SIL2 certification, CE certification, CNAS metrology authentication 7. Support a variety of wireless communications: GPRS, LORA, WIFI, ZIGBEE, NB-IoT, 4G, 5G (optional) 8. Dual temperature and humidity design, physical + software dual temperature and humidity compensation, real-time detection and display transmission 9. Bilingual operating system: Chinese and English system switching 10. Support a variety of installation methods: Wall-Mounted, rod, ceiling, pipeline, etc 11. Black box storage function: operation record, alarm record, over-temperature use record, over-range use record 12. Reminder and alarm functions are complete: Sensor expiration reminder, super concentration alarm, super temperature alarm, super humidity alarm, fault alarm, instrument calibration reminder, etc 13. Use the guide function on the operation interface to prevent misoperation 14. Zero automatic correction function 15. Waterproof, dustproof, anti-static, anti-electromagnetic interference, special models have anti-cross gas interference
The Pathfinder series fixed Gas detector detects the gas concentration and temperature and humidity on site, converts it into a standard signal (such as 4-20mA, RS-485, etc.), and then transmits it to the PLC, DCS, alarm control host and other host computers for unified display, management and control, thus forming an intelligent Gas detection alarm control system. Built-in relays can control peripheral equipment, such as sound and light alarms, fans, solenoid valves, etc.
Petroleum and petrochemical, mining, gas, aerospace and military, chemical industry, electric power, scientific research institutes, municipal engineering, metallurgy
Measurement equipment CPA, CCCF, Flameproof, Intrinsic Safety (IS), IP66 protection, Mine safety, Coal safety, ROSH, SIL2, CE, ATEX, IEC
1. Installation equipment: choose Wall-Mounted, rod, ceiling or pipeline installation methods 2. Connect power supply: use 12~ 36VDC power supply (typical 24VDC), optional external battery 3. Configuration parameters: set detection parameters, alarm values, etc. through infrared remote control or remote IoT 4. Networking settings: optional WIFI, LORA, GPRS/4G/NB-IoT, 5G and other wireless communications for remote configuration 5. Start detection: The device automatically starts to detect gas concentration and temperature and humidity, and outputs a signal 6. Monitoring data: Monitor real-time data through the display screen or remotely connect to the Empaer server 7. Handle alarms: Take corresponding measures according to alarm functions (e.g. light alarms, sound and light alarms) 8. Regular Maintenance: It is recommended to calibrate annually and check the status of the Sensor
- Ensure that the working Ambient Temperature is in the range of -40~ 55 ℃, humidity 10% -95% RH (no condensation) - Check the power supply voltage before use to avoid exceeding the range of 12~ 36VDC - Periodic calibration with a recommended period of 1 year to ensure detection accuracy - Avoid use in strong electromagnetic interference environments to prevent affecting equipment performance - Special models have anti-cross gas interference, general models need to pay attention to cross-interference issues - Follow the interface guidelines during operation to prevent misoperation Storage temperature should be maintained between -10 and 30 degrees Celsius - Device power consumption is less than 2W, depending on the Sensor, consult customer service before use - When installing separately, the maximum distance between the watch head and the Probe is 100 meters. For details, please consult customer service. - Wireless communication function is optional and needs to be configured according to actual needs
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.