$ 684.00Ex works
With explosion-proof IP66 Protection Rating, support 4G remote control and paraMeter configuration. The visual distance of the high definition color screen is 10 Meters, the Response Time T90 ≤ the national standard, the detection accuracy ≤ +/- 3% FS, suitable for a variety of installation methods.
Category : Gas Detector
Brand : Empaer
SKU : NB049651
Service :The delivery and service By NBCLab.Com
The Empaer APEG-D-CH2O (4G) Volkswagen series fixed formaldehyde detector is a cost-effective, high-performance on-site gas monitoring instrument for formaldehyde Gas detection. The device converts the detected gas concentration into a standard signal and transmits it to the host computer system. The built-in relay can control the peripheral equipment, and supports remote monitoring, alarm value setting and calibration functions.
1. Star product for more than 10 years of precipitation, IoT design, explosion-proof grade Exd II C T6, EX TD A21, Protection Rating IP66. 2. Appearance design with independent intellectual property rights, high brand recognition. 3. High performance, in line with a variety of industry standards, widely used and stable. 4. Ultra high definition color display, viewing distance ≥ 10 meters. 5. Supports a variety of wired and wireless communication output methods, including 4G, NB-IoT, WIFI, etc. 6. Bilingual operating system, supports switching between Chinese and English. 7. Remote control function, allowing for parameter configuration and program upgrades. 8. Protection functions include intermittent detection and Sensor automatic protection (optional). 9. Black box function, recording operation, alarm, over-temperature and over-range use. 10. Complete reminders and alarm functions, such as Sensor expiration, over-concentration, over-temperature, fault and calibration reminders. 11. Humanized operation guidelines to prevent misoperation. 12. Zero automatic correction function. 13. Dual operation mode: button and infrared remote control. 14. Easy to install, support Wall-Mounted, ceiling type, pipeline type, etc. 15. Waterproof, dustproof, anti-static, anti-electromagnetic interference, special anti-cross gas interference.
The detector detects the concentration of formaldehyde gas on site, converts it into a standard signal (such as 4-20mA, RS-485, etc.), and transmits it to the host computer system such as PLC, DCS or alarm control host for unified display, management and control. The built-in relay can be linked to sound and light alarms, fans or solenoid valves and other equipment to realize intelligent Gas detection and alarm control.
Petroleum and petrochemical, gas, aerospace and military industry, chemical industry, electric power, scientific research institutes, municipal engineering, mining, metallurgy
Measurement equipment CPA, CCCF, Flameproof, Intrinsic Safety (IS), IP66 protection, Mine safety, Coal safety, ROSH, SIL2, CE, ATEX, IEC
1. To install the equipment, choose Wall-Mounted, ceiling or pipeline installation methods. 2. Connect the power supply (12~ 36VDC typical power supply 24VDC) and the signal output line. 3. Initial setup by pressing buttons or infrared remote control, including language selection (Chinese/English). 4. Configure alarm values and remote parameters (e.g. via 4G, NB-IoT, or WiFi). 5. Start the equipment for gas concentration detection and monitoring. 6. Periodic calibration (recommended cycle of 1 year) and program upgrades.
• Ensure that the working Ambient Temperature is between -40~ 55 ℃ and the humidity is 10% -95% RH without condensation during installation. • Avoid use under operating pressure (86-106KPA) or extreme storage temperatures (-10-30 ° C). • Confirm the sensor type and range (0~ 10ppm) before use, and consult the customer service of the mall for specific parameters. • Pay attention to cyber security when remote control to prevent unauthorized access. • Regularly check the Protection Rating and explosion-proof performance to ensure that the equipment is in good condition. • Follow humanized guidelines during operation to prevent malfunctions caused by misoperation. During the calibration and upgrade process, user-set parameters will not be lost, but it is still recommended to back up important data.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.