Please contact customer service
Using PID full digital automatic control, the temperature conversion time is as fast as 10 seconds, the test range is -40 ° C to 150 ° C, and it can be programmed arbitrarily to meet the resistance test requirements of materials in extremely cold and extremely hot environments.
Category : Thermal Shock Test Chamber
Brand : Factory
SKU : NB049733
Service :The delivery and service By NBCLab.Com
The NBC-LC-50L Thermal Shock Test Chamber is mainly used to test the resistance of materials to extremely high temperature or extremely low temperature, simulating the situation of discontinuous high temperature or low temperature, and can complete the test in a short time. The equipment is an essential test equipment for metal, plastic, rubber, electronics and other material industries. It is used to detect chemical changes or physical damage caused by thermal expansion and contraction of samples. It is divided into two-box and three-box. The product adopts PID system to realize full digital automatic control and easy operation.
1. Adopt PID system to achieve full digital automatic control, easy to operate. 2. The test temperature has a wide impact range, from -40 ° C to + 150 ° C, which can be programmed arbitrarily. 3. Fast temperature conversion time, 10 seconds (time can be specified). 4. The controller has high control accuracy, up to +/- 0.2 ℃. 5. The inner box is made of SUS #304 thickened heat-resistant and cold-resistant stainless steel plate and a first-class light panel. 6. The thermal insulation material adopts high-density Glass cotton and high-strength PU foam insulation material, and the thermal insulation effect is good. 7. The heater adopts U-shaped fin type 304 #seamless steel high-speed heating electric heater, with fast heating rate. 8. The air supply circulation system adopts a Japanese multi-blade centrifugal circulating fan and a Japanese motor as a whole. 9. The refrigeration Compressor adopts imported Compressor units, and the refrigeration accessories include table bending middle force evaporator, Marr fan, etc. 10. The temperature and humidity control instrument adopts programmable console controller, Touchscreen input, and supports Chinese and English switching. 11. The wiring method is implemented in accordance with international electrical standards. 12. With multiple protection devices, including Compressor overheating, overtemperature, overload, high voltage, low pressure, oil pressure, overcurrent, less equal.
Through the structural design of high temperature zone, low temperature zone and test zone, the test sample can be quickly converted between extremely high temperature and extremely low temperature environment under the load of the hanging basket (the conversion time can be as short as 10 seconds), simulating the thermal Impact environment. The thermal shock effect generated by it may lead to physical damage or electrochemistry changes such as cracking, layer breaking, displacement of the finished product. The equipment adopts a PID control system to precisely control the temperature to detect chemical changes or physical damage caused by thermal expansion and contraction of the material.
Electronics components, automation components, communication components, auto parts, metals, chemical materials, plastics, defense industry, aerospace, military industry, BGA, PCB substrate, electronic chip IC, semiconductor ceramic and polymer materials
GB/T 2423.1 - 2008 Test A, GB/T 2423.2 - 2008 Test B, GB-T10592-2008, GJB150.3-198, GJB360A-96 Method 107 Temperature impact test, GJB150.5-86 Temperature impact test, GB-2423.1-89 (IEC68-2-1) Test A: Low temperature test method, GB-2423.2-89 (IEC68-2-2) Test B: High temperature test method, GJB360.8-87 (MIL-STD-202F) high temperature life test, GBJ150.3 (MIL-STD-810D) high temperature test method, GJB150.4 (MIL-STD-810D) low temperature test method, GJB150.3-86, GJB150.4-86, GJB150.5-86, MIL, IEC, JIS specifications
The specific operation steps are not explicitly mentioned in the information.
* The load-bearing capacity of the hanging basket must be within 20Kg. If the cooling method chooses Water-Cooled heat dissipation, the buyer needs to install water towers, pipes and other facilities by himself. The power supply of the equipment is AC380V, 50~ 60Hz, and the power is 18KW. It is necessary to ensure that the power supply meets the requirements. When operating, it is necessary to pay attention to the status of multiple protection devices of the equipment to ensure safe operation.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.