Overview
Shangtian Jingyi JA62002 One Percent Electronic Balance is a High Accuracy weighing equipment, Capacity 6200g, readability accuracy 0.01g, using a new generation of High Accuracy Sensor to ensure stable and reliable weighing results. Equipped with backlit high definition LCD LCD display, the display is clear and intuitive, suitable for laboratories, industries and other weighing scenarios.
Features
1. A New Generation of High Accuracy Sensors, Providing Stable and Reliable Weighing Results
2. Backlit high definition LCD LCD display, weighing results are clearly displayed
3. Front horizontal bubble adjustment, simple and intuitive operation
4. External calibrating function
5. The weighing stability time and reaction speed are adjustable, and the reaction time is < 2S
6. Various weighing units: mg/g/ct/oz, etc
7. Standard RS232 interface, optional PC-STWC function to transfer weighing data directly to open applications such as Excel
8. Power supply: 110V-240V, 50Hz/60Hz
9. Optional functions: dynamic weighing, USB storage, lower hook, battery, printer, second display screen, Draft Shield, check and alarm light, etc
Principle
The Electronic Balance is based on High Accuracy Sensor technology, which converts mechanical signals into electrical signals by sensing the pressure of the weighing object on the pan, and displays the precise weight on the LCD display after internal processing. The external calibrating function ensures accuracy in long-term use, and the response time is adjustable to optimize the weighing efficiency.
Applications
Laboratory, industrial, pharmaceutical, food, chemical, education, quality control
Steps
1. Place the Balance on the horizontal countertop and adjust it to the horizontal state through the front horizontal bubble
2. Connect Power Adapter, input voltage 110-240V, output 12V1A
3. Boot preheating to ensure that the operating temperature is within the range of 10~ 30 ° C
4. If you need to calibrate, use the external calibrate function to calibrate
5. Place the object to be weighed on the pan and wait for the stable weight display
6. Switch the weighing unit as needed (mg/g/ct/oz, etc.)
7. Optional connection to RS232 interface or PC-STWC function to transmit data
Notice
• Ensure that the working Ambient Temperature is between 10 and 30 ° C to avoid extreme temperature affecting the accuracy
• Be sure to adjust the Balance to the horizontal state through the horizontal bubble before use to prevent weighing errors
• Power Adapter input voltage range is 110-240V, output is 12V1A, do not use beyond the range
• Calibrating requires the use of an external calibrating function, which is performed regularly to maintain accuracy
• Avoid overloading, Capacity does not exceed 6200g
• Do not use corrosive solvents when cleaning, keep the pan and fuselage drying
• Optional functions such as Draft Shield, battery, etc. need to be installed and used according to the instructions