Please contact customer service
Adopt PID full digital automatic Control system, Temperature control accuracy of +/- 0.2 ℃. With 10 seconds fast temperature conversion ability, Temperature range covers -40 ℃ to 150 ℃, to meet a number of national military standards and international standards testing requirements.
Category : Thermal Shock Test Chamber
Brand : AISRY
SKU : NB050097
Service :The delivery and service By NBCLab.Com
The NBC-LC-100L Thermal Shock Test Chamber is mainly used to test the resistance of materials to extremely high temperature or extremely low temperature. It simulates the situation that the product is not continuously in high temperature or low temperature, and can complete the test in a short time. This equipment is an essential test equipment for metal, plastic, rubber, electronics and other material industries. It is used to detect chemical changes or physical damage caused by thermal expansion and contraction of the sample. The product is divided into two-box and three-box type, and adopts PID full digital automatic control system, which is easy to operate.
1. Adopt PID full digital automatic control system, easy to operate. 2. The temperature conversion time is fast, and the time can be specified. 3. The inner box is made of SUS #304 thickened heat-resistant and cold-resistant stainless steel plate and a first-class light panel. 4. The thermal insulation material adopts high-density Glass cotton and high-strength PU foam insulation material, and the thermal insulation effect is good. 5. The air supply circulation system adopts a Japanese multi-blade centrifugal circulating fan and a Japanese motor as a whole. 6. The heater adopts U-shaped fin type 304 #seamless steel high-speed heating electric heater. 7. The refrigeration Compressor adopts imported Compressor units, and the refrigeration accessories include table bending middle force evaporator, Marr fan, etc. 8. Equipped with a variety of protective devices, such as Compressor overheating, overtemperature, overload, high voltage, low pressure, oil pressure, overcurrent, underphase, power failure standby and other alarm warnings. 9. The temperature and humidity control instrument adopts programmable platform controller, Touchscreen input, supports Chinese and English switching, and can arbitrarily set different temperature points according to customer requirements.
The Thermal Shock Test Chamber simulates extremely high and very low temperature Impact environments by rapidly transitioning the test sample between the high and low temperature regions. The device uses a PID control system to precisely control the temperature, so that the sample experiences severe temperature changes in an instant to test the chemical changes or physical damage caused by the thermal expansion and contraction of the material structure or composite, such as cracking, breaking, displacement or electrochemical changes.
Electronics components, automation components, communication components, auto parts, metals, chemical materials, plastics, national defense industry, aerospace, military industry, BGA, PCB base wrench, electronic chip IC, semiconductor ceramic and polymer materials
GB/T 2423.1 - 2008 Test A, GB/T 2423.2 - 2008 Test B, GB-T10592-2008, GJB150.3-198, GJB360A-96 Method 107 Temperature impact test, GJB150.5-86 Temperature impact test, GB-2423.1-89 (IEC68-2-1) Test A: Low temperature test method, GB-2423.2-89 (IEC68-2-2) Test B: High temperature test method, GJB360.8-87 (MIL-STD-202F) high temperature life test, GBJ150.3 (MIL-STD-810D) high temperature test method, GJB150.4 (MIL-STD-810D) low temperature test method, GJB150.3-86, GJB150.4-86, GJB150.5-86, MIL, IEC, JIS specifications
The information does not provide specific operation steps.
The cooling method can be Air-Cooled or Water-Cooled for heat dissipation. If you choose Water-Cooled, you need to install water towers and pipes by yourself. * The power requirements are AC380V, 50~ 60Hz, and the power is 18KW. The equipment is equipped with a variety of protective devices, and should be dealt with promptly when an alarm occurs.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.