$ 6447.00Ex works
Adopt equilibrating Conditioning Control system, Temperature range -60 ℃~ + 150 ℃, Humidity range 20~ 98% R.H., with energy saving function and comprehensive protection system to ensure long-term accurate and stable operation.
Category : Temperature Humidity Chamber
Brand : AISRY
SKU : NB050541
Service :The delivery and service By NBCLab.Com
Split constant temperature and humidity testing machine (model NBC-100L-60/2) is mainly used to test the performance of materials in various environments, test heat resistance, cold resistance, dry resistance and moisture resistance characteristics. It is suitable for mass inspection of products in the fields of electronics, electrical appliances, communications, instrumentation, vehicles, plastic products, metals, food, chemistry, building materials, aerospace and other fields. Adopt equilibrate Conditioning Control system (BTHC), transmit the data in the box to the controller through the induction system, control SSR to realize multi-stage intelligent output, equilibrate temperature Humidity system Power, ensure stable thermal insulation Humidity and energy saving.
1. The product has beautiful appearance, reasonable structure, precise process, simple and convenient operation, stable and reliable performance. The controller uses a large color liquid crystal man-machine touch dialog LCD interface, which supports Chinese and English display and RS232 computer remote control. 3. The refrigeration circulation system adopts the original imported Japanese Sanyo fully enclosed Compressor (optional French Taikang), and the components are imported from Japan, France, the United States, Italy, etc., using American environmentally friendly refrigerants R23A and R404A. 4. Reserve a 50mm diameter test hole on the left side of the box. 5, With Fully Automatic, High Precision System Loop, P.L.C Lock Processing and P.I.D Automatic Calculation Control, High Accuracy Temperature, High Stability. 6. Specially designed air circulation system and sensing system ensure uniform temperature without dead ends. 7. Adopt enlarged observation window, 4 layers of whole empty tempered Glass, wide field of vision. 8. Comprehensive protection system includes power overload, leakage, control loop overload, short circuit, Compressor, grounding, over temperature protection and alarm prompt, automatic display fault and shutdown.
Using equilibrate Conditioning Control system (BTHC), the induction system transmits the actual data in the test Chamber to the controller. The controller realizes multi-stage intelligent output by controlling the SSR, and the output power of the equilibrate temperature Humidity system ensures that the temperature Humidity in the test Chamber is fully stable. The system has energy saving function, reduces the use of Power, and ensures long-term accurate and stable operation of the instrument.
Electronics, electrical appliances, communications, instrumentation, vehicles, plastic products, metals, food, chemicals, building materials, aerospace
Connect the power supply and check that the voltage meets the requirements (220V/50HZ, allowing a change of +/- 10%). 2. Set the temperature and Humidity parameters through the controller and use the touch interface to operate. 3. Place the test sample on the shelf, adjust the spacing or remove the shelf. 4. Start the instrument, monitor the running status, and ensure that the insulation Humidity is stable. 5. After the test is completed, turn off the instrument and disconnect the power supply.
• Operating Environment Temperature should be kept at 0~ 30 ℃, and the performance guarantee environment is 5~ 25 ℃. • Miscellaneous items should not be placed within 60cm of the instrument to avoid affecting the operation. • Regularly check the water quality of the humidification system to filtrate and avoid blockage. • Use the bottom universal wheel when moving the instrument, pay attention to shock absorption and load-bearing. • When a fault occurs, the controller automatically displays the fault point and stops, which needs to be dealt with in time. • The humidification system can dry burn for 1 hour when there is a lack of water, but it needs to be used with a high temperature alarm module.
We recommend the NBC-100L-60/2 Split-type Constant Temperature and Humidity Test Chamber. This equipment offers a wide range of temperature and humidity control (-60~150°C, 20~98% RH), enabling precise simulation of extreme environments, making it ideal for heat resistance, cold resistance, and moisture resistance testing of electronic products. It utilizes a balanced temperature and humidity control system and an imported compressor to ensure accurate and stable test data, helping you effectively evaluate product quality.
Yes, the NBC-100L-60/2 Split-Type Constant Temperature and Humidity Test Chamber adopts a split-type design, separating the main chamber from the refrigeration unit, allowing flexible adaptation to limited spaces. It features an inner chamber volume of 100L, a compact exterior, and is equipped with universal wheels at the bottom for easy mobility. This instrument is widely used for material testing, and its precise temperature and humidity control, along with a uniform circulating air system, ensure accurate performance evaluation of materials under alternating environmental conditions.
It is recommended to choose the NBC-100L-60/2. It features a color LCD touch screen with Chinese and English display, making operation simple. In terms of functionality, it offers fully automatic PID calculation control and multiple safety protections (such as over-temperature and leakage protection), ensuring long-term stable operation. Additionally, its circular split-type humidifier and water circulation system not only prevent freezing issues but also save water and enhance durability, making it suitable for applications requiring continuous and reliable testing.