$ 751.00Ex works
Using electrochemistry gas Sensor, Response speed, Measurement accuracy. Support 4-20mA, RS485 and other signal output, with overvoltage, lightning protection, short circuit and other multiple circuit protection functions, remote monitoring and data query.
Category : Gas Detector
Brand : KORNO
SKU : NB050805
Service :The delivery and service By NBCLab.Com
The MOT200 Hydrogen Cyanide Detection Alarm Meter is suitable for detecting hydrogen cyanide gas concentrations in various environments. It utilizes electrochemical gas sensors and microcontroller technology, featuring fast response times, high measurement accuracy, and excellent stability and repeatability. The instrument is equipped with a 2.4-inch industrial-grade color screen that displays technical indicators and gas concentration values, along with multiple circuit protection functions. It can be connected to an online environmental monitoring platform, enabling remote monitoring, control, and alarm through various transmission methods. The device supports data query and management on computers, mobile phones, and other devices.
1. Adopts a new semiconductor nano-process ultra-low-power 32-bit microprocessor. 2. Features a 2.4-inch industrial-grade color screen with a resolution of 320x240, supporting free switching between PPM, %VOL, and mg/m³ concentration units. 3. Multiple signal output options: 4-20mA, RS485, 0-5V, 0-10V, frequency signal, and switching signal. 4. Multiple transmission methods: 3-4 core cable, fiber optic, network cable, GPRS transmission, wireless transmission, and video transmission. 5. Multiple data reception methods: user computers, control alarms, PLC, DCS, mobile phones, tablets, etc. 6. Equipped with status indication function and four sets of LED status indicator lights. 7. Includes overvoltage protection, lightning protection, short-circuit protection, reverse connection protection, anti-static interference, anti-magnetic interference, and automatic recovery functions. 8. Features temperature and humidity detection function, capable of measuring the temperature and humidity of gases on-site or in pipelines (optional). 9. Fully software-automatic calibration with up to 6-level target point calibration for sensors, ensuring measurement accuracy and linearity, and includes data recovery function. 10. Fully Chinese/English operation menu, simple and practical, with temperature compensation function. 11. Optional infrared remote control for non-intrusive remote operation of the instrument.
This instrument utilizes an electrochemical gas sensor to detect the concentration of hydrogen cyanide gas in the environment. The sensor converts the gas concentration signal into an electrical signal, which is then collected, processed, and calculated by the built-in microcontroller. The concentration value is displayed in real-time on the screen and can be transmitted via multiple signal output interfaces.
Suitable for various environments requiring the detection of hydrogen cyanide gas concentration.
1. Select an appropriate installation location and method based on the site environment and requirements. 2. Connect the power supply and link the signal output line according to the chosen transmission method (such as cable, network cable, GPRS, etc.). 3. After powering on, configure parameters through the instrument menu or the optional infrared remote control, including unit selection, alarm threshold settings, etc. 4. Once the instrument enters normal operation, it will monitor and display the hydrogen cyanide gas concentration and temperature/humidity (if equipped) in real time. 5. Regularly perform automatic calibration via software or use the up to 6-point calibration function to ensure measurement accuracy. 6. Remote data queries, historical data retrieval, and device status monitoring can be conducted through connected computers, mobile apps, or a central control platform.
• During installation, ensure the instrument is kept away from sources of strong static electricity and strong magnetic field interference. • When wiring, pay attention to the polarity of the power and signal cables. The instrument has reverse connection protection, but correct connection is still recommended. • In areas with frequent lightning, it is recommended to ensure the lightning protection function of the instrument is properly activated. • Regular calibration is key to ensuring measurement accuracy. Please follow the operational steps to perform it. • Avoid manual impact or the use of non-specified accessories during operation to prevent damage to the instrument. • The optional temperature and humidity detection function must be specified at the time of ordering and is not part of the standard configuration.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.