$ 2255.00Ex works
Adopt no heat circulation pump to avoid its own heat production, temperature control accuracy +/- 0.1 ℃, cooling capacity up to 4000W. Equipped with large screen backlight LCD display, 304 stainless steel liner, multiple safety protection, with power-off protection and over-temperature alarm function.
Category : Thermostatic Bath
Brand : HuXi
SKU : NB050917
Service :The delivery and service By NBCLab.Com
The HLC-3020 constant temperature bath from Huxi adopts an internationally advanced refrigeration system, ensuring stable and reliable performance. Its principle involves using the outlet to externally channel the constant temperature medium inside the bath through insulated hoses, creating an external constant temperature environment. This provides a stable and uniform temperature liquid environment with circulating coolant for testing experiments or production, and the coolant can be recycled and reused. This instrument is widely used in research departments such as petroleum, chemical engineering, electronic instrumentation, physics, chemistry, bioengineering, healthcare, life sciences, light industry and food, physical property testing, and chemical analysis. It is also suitable for universities, enterprise quality inspection and production departments, providing users with a controlled hot and cold environment with uniform and constant temperature for testing or conducting constant temperature experiments on samples or products. Additionally, it can serve as a direct or auxiliary heat source or cold source for heating or refrigeration.
1. Large-screen backlit LCD display showing set temperature, actual temperature, independent activation/deactivation of functions such as "heating," "cooling," and "internal/external circulation," with clear and concise working status information. 2. The control section features ABS molded design, with an overall streamlined exterior for an aesthetically pleasing appearance. The finely crafted front panel and tabletop, along with the unique ergonomic R-rounded corner design, prevent operators from accidentally injurying themselves on sharp edges. Packaging uses molded foam, with upper and lower molds, to prevent damage during transport. 3. High-performance stirring circulation motor with low noise, low heat generation, fully enclosed, and long service life. Utilizes a heat-free circulation pump to avoid temperature fluctuations in the bath caused by heat generated by traditional water pumps. 4. 304 stainless steel tabletop and inner tank, with the cooling coil offering positioning and surface treatment technology to effectively prevent shaking during transport or use, as well as reduce corrosion or rust. 5. Fully enclosed motor impeller to avoid safety hazards. Multi-level safety protection: low liquid level dry-burning protection for heating tubes, with both light and sound alarms during alerts. 6. Features power-off protection and over-temperature alarm, offering multiple safety measures. 7. Fully enclosed compressor refrigeration system with overheat and overcurrent multi-protection devices. 8. The instrument is specifically designed with removable door panels on all sides for easy cleaning after extended operation, simplifying dust removal and requiring no disassembly tools, ensuring better cooling effect. 9. The instrument operates stably and reliably, is easy and safe to use, and includes temperature calibration and self-tuning functionality. 10. All circulation interfaces and drains use 304 stainless steel barbed fittings for quick and reliable installation. The drain valve is designed to be built-in and hidden, ensuring an attractive appearance and effectively preventing unnecessary damage during shipping or transport. 11. The instrument is equipped with two lengths of circulation silicone tubing and insulation sleeves as standard, allowing flexible use by customers.
The constant temperature bath circulates and maintains the temperature of the liquid medium inside the tank through a high-pressure pump, enhancing temperature uniformity and reducing fluctuations. Its principle involves using a water outlet to channel the constant-temperature medium housed in the tank through an insulated hose, establishing an external constant temperature system. This provides a stable-temperature coolant fluid for testing experiments or production, creating a liquid environment with uniform and constant temperature. The coolant can be recycled and reused. It features both internal and external circulation functions: the internal circulation allows direct constant temperature testing of test samples or production products inside the tank, while the external circulation function uses a high-pressure pump to cycle and maintain the temperature of the liquid medium, improving temperature uniformity and reducing temperature fluctuations.
Research departments such as petroleum, chemical engineering, electronic instrumentation, physics, chemistry, bioengineering, hygiene, life sciences, light industry and food, physical property testing, and chemical analysis, as well as higher education institutions, enterprise quality inspection, and production departments.
1. Check that the instrument's appearance and accessories are intact, and ensure all interfaces are securely connected; 2. Connect the circulation interface and drainage port (installed with 304 stainless steel barbed connectors); 3. Connect the insulated hoses for internal or external circulation as needed; 4. Connect the power supply and set the desired temperature via the large backlit LCD display interface; 5. Activate the "Heating" or "Cooling" function, and select either "Internal circulation" or "External circulation" mode as required; 6. The instrument will operate automatically. Once stable, proceed with the experiment or production test. Note: Refer to the instrument user manual for specific operation instructions to ensure correct and safe usage.
- Confirm that the power connection meets requirements before use; - Be aware of the low liquid level dry-heating protection for the heating tube to avoid operation when the liquid level is too low; - The instrument is equipped with power failure protection and over-temperature alarm functions; handle abnormalities promptly; - The fully enclosed compressor unit has a refrigeration system protection to prevent overheating or overcurrent; - Clean dust regularly, utilizing the flexible door panel design for easy disassembly and cleaning; - After use, turn off all functions, disconnect the power, and drain the liquid in the tank to maintain cleanliness; - For the instrument's temperature calibration and self-tuning functions, it is recommended to perform regular maintenance according to the manual; - Do not disassemble the internal parts of the instrument without authorization; contact professionals if issues arise; - During transportation, use molded foam packaging to avoid damage; - Ensure that the drain valve is built-in and hidden to prevent damage during transport.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.