$ 1437.00Ex works
30L large capacity water tank, Temperature range -5~ 100 ℃, temperature control accuracy +/- 0.1 ℃, with internal and external circulation function, no heat circulation pump to avoid the influence of temperature field, fully enclosed compressor unit refrigeration, with over-temperature alarm and low level protection, 304 stainless steel liner corrosion resistance.
Category : Thermostatic Bath
Brand : HuXi
SKU : NB050929
Service :The delivery and service By NBCLab.Com
The constant temperature bath adopts an internationally advanced new refrigeration system, offering stable and reliable performance. It features both internal and external circulation functions. The internal circulation allows for constant temperature testing or experiments directly within the bath, while the external circulation uses a high-pressure pump to circulate the liquid medium in the bath, enhancing uniformity and reducing temperature fluctuations. This instrument is widely used in research departments, universities, corporate quality inspection and production departments in fields such as petroleum, chemical engineering, electronic instrumentation, physics, chemistry, bioengineering, healthcare, life sciences, light industry, food, physical property testing, and chemical analysis. It provides users with a temperature-controlled, uniformly stable liquid environment. It can also be used as a heat or cold source for direct or auxiliary heating and cooling.
1. Large backlit LCD display allows independent start/close of "Heating," "Cooling," "Internal/External Circulation," and other functions. 2. ABS mold-based control section design with a streamlined appearance and R-rounded corners to prevent operator injury. 3. Packaged with molded foam upper and lower molds to prevent damage during transportation. 4. High-performance stirring circulation motor with low noise, low heat generation, fully enclosed design, and long lifespan. 5. Adopts a heat-free circulation pump to avoid temperature field interference caused by traditional water pump heat generation. 6. 304 stainless steel worktable and inner tank, cooling coil with added positioning and surface treatment to resist corrosion and rust. 7. Fully enclosed motor impeller provides safety protection: low-liquid level dry-heating protection for the heating tube, with both light and sound alarms. 8. Equipped with power-off protection and over-temperature alarm function. 9. Fully enclosed compressor unit for cooling, with multiple protections against overheating and overcurrent. 10. Side panels are flexible for easy removal and cleaning of dust. 11. Instrument features temperature calibration and self-tuning functions. 12. Circulation interface and drain port use 304 stainless steel barbed connectors, with the drain valve hidden for safety. 13. Standardly equipped with two sections of silicone circulating tubing and insulation sleeves for convenience.
The constant temperature medium in the tank is externally drawn through the outlet via an insulated hose to establish an external constant temperature environment, providing a uniform and stable-temperature cooling fluid for testing experiments or production. The constant-temperature cooling fluid can be circulated and reused. The external circulation uses a high-pressure pump to circulate and maintain the temperature of the liquid medium in the tank, enhancing temperature uniformity and reducing fluctuations.
Research institutions, higher education institutions, enterprise quality inspection, and production departments in fields such as petroleum, chemical engineering, electronic instrumentation, physics, chemistry, bioengineering, health, life sciences, light industry and food, physical property testing, and chemical analysis.
1. Place the instrument on a well-ventilated, stable workbench. 2. Connect the power supply and verify that the voltage meets the requirements. 3. Inject an appropriate amount of liquid medium into the tank, ensuring the liquid level is above the safety line of the heating tube or refrigeration coil. 4. Set the desired temperature via the LCD screen according to the experimental requirements. 5. Select and activate the "Heating" or "Cooling" function. 6. For external circulation, connect the insulated hose to the circulation port and activate the "External Circulation" function. 7. Wait for the temperature to stabilize at the set value, then place the sample inside the tank or conduct the experiment via external circulation. 8. After use, turn off the "Heating," "Cooling," and "External Circulation" functions, and disconnect the power supply. 9. Drain the liquid medium using the built-in hidden drain valve, and clean the instrument.
- Ensure the liquid level is always above the heating tube or cooling coil to prevent dry burning or damage. - Before use, check that the power connection is secure and the voltage matches. - Avoid touching the edges of the instrument during operation to prevent injury. - After prolonged use, regularly clean the dust inside the surrounding door panels to maintain cooling efficiency. - When using external circulation, ensure the insulation hose is securely connected to prevent leaks. - If the instrument alarms, stop using it immediately and check the cause. - For transport or storage, use the original molded foam packaging to avoid damage. - When draining, use the built-in hidden drain valve and store the liquid safely. - Avoid using this instrument in humid or explosive environments. - This instrument is intended for professional use only; keep it away from children.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
