Using high-efficiency reverse osmosis (RO) technology, the removal rate is ≥ 96%; equipped with three-stage pure water quality conductivity < 5μs/cm; brand silent pump to reduce noise; four-stage filtrating system and inert material to avoid secondary pollution.
Category : Laboratory Pure Water System
Brand : HuiNuo
SKU : NB051009
Service :The delivery and service By NBCLab.Com
HN-UV-SPRAY Lab water purifier adopts advanced reverse osmosis (RO) (RO) water treatment technology, combined with a four-stage precision filtrate system, to provide stable and reliable three-stage pure water for the laboratory. The equipment is scientifically designed, operates quietly, and is easy to maintain. It is suitable for a variety of experimental and analytical scenarios.
1. High-efficiency reverse osmosis (RO) technology: using high-quality RO film to remove fine impurities, colloids, organic matter, heavy metals, soluble solids, bacteria, viruses, pyrogen and other harmful substances in raw water, with a removal rate of ≥ 96%. 2. Brand high voltage silent pump: low noise, small vibration, long life, stable and reliable operation. 3. Replaceable pretreatment filter element: convenient replacement design, stable filtrating effect, cost-effective replacement. 4. Online water quality monitoring: Equipped with a digital display panel, the effluent quality is monitored in real time, and the data is accurate and intuitive. 5. Inert material sealing system: Pipes and joints are made of PE and POM inert materials to effectively avoid secondary pollution. 6. Three-dimensional optimized structural design: The internal pipeline connection path is the shortest, reducing residual water residue and ensuring better water quality of the finished product. 7. Fully automatic operation: the water tank will automatically stop when it is full of water, automatically start when the water level drops, and automatically stand by when the raw water stops or the water pressure is too low, which is safe and energy-saving. 8. Four-stage precision filtrating system: including PP precision filter, CTO activated carbon filter, RO reverse osmosis (RO) membrane, ultra-purified column, each performing its duties to ensure water quality.
The equipment uses reverse osmosis (RO) water treatment technology to gradually purify the raw water through a four-stage precision filtrate system. First, the PP precision filter intercepts the particulate matter (PM) ≥ 1 μm, then the CTO activated carbon filter element removes chemical substances and odors, and then filters heavy metals, bacteria, viruses and heat sources through the RO reverse osmosis (RO) membrane (pore size 0.0001 μm). Finally, the ultra-purified column further improves the water quality and removes residual ions and organic matter. The fully automatic control system automatically starts and stops according to the water level and raw water pressure to ensure efficient and safe operation.
Physical and chemical analysis experiments, biological experiments, environment monitoring, food testing, teaching and research, industrial laboratories, laboratory equipment cleaning, small pure water supply
1. Confirm that the raw water quality meets the requirements (TDS ≤ 200mg/L, residual chlorine, iron, manganese and other indicators do not exceed the standard). 2. Connect the raw water supply pipe to ensure that the water pressure is normal. 3. Turn on the power supply, turn on the device switch, and start the digital display panel. 4. Observe the water quality data displayed on the panel and wait for the system to automatically make water until the tank is full. 5. Open the water outlet valve during use to access three-stage pure water. 6. Regularly check and replace the pretreatment filter element to maintain the filtrating effect.
There are certain requirements for the raw water conditions, and failure to meet the parameters or working conditions may lead to fouling or damage to the membrane module. When the quality of raw water exceeds the specifications, it is recommended to choose an enhanced pre-treatment equipment. The water production speed is affected by the water pressure of the water supply and the use of the filter element. - If the raw water TDS exceeds 200mg/L or residual chlorine, iron, manganese and other indicators exceed the standard, enhanced pretreatment is required. - If the raw water TDS exceeds 200ppm, it is recommended to choose an enhanced pretreatment or a Miscellaneous series ultra-pure water machine. Make sure that the raw water quality meets the parameter requirements to ensure the normal operation of the equipment. - Membrane module contamination or damage caused by non-compliance with raw water requirements is not covered by quality assurance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.