WGG60-E4 Glossiness Meter is a gloss measurement instrument designed and manufactured by JND brand with reference to international standard ISO 2813 and Chinese national standard GB/T9754. The Gloss value of the instrument can be Traceability from the Glossiness benchmark of Shanghai Institute of Measurement and Testing Technology, and all performance indicators meet the requirements of the second-level working machine in the national standard JJG 696-2002 Measurement verification specification.
Features
1. Using imported chips, the efficiency is as high as 97%, and it can be used continuously for up to 48 hours on a complete charge. It can be charged once a month for normal daily use.
2. With on-site error compensation function design, it can effectively eliminate errors to ensure accurate and reliable measurement data.
3. National first-class standard black (high) white (low) Calibration plate, in line with national standards, can easily pass Measurement verification.
4. Adopt professional optical path design, stable and reliable measurement data, minimal Inter-instrument Agreement and excellent reproducibility.
5. Ergonomic shell, ingenious center configuration echoes the shell, making measurement handy. Upgrade button, that is, open and test.
6. Ultra-wide voltage, covering the world.
7. The soft surface treatment of the bottom probe effectively prevents scratching the tested item.
Principle
Based on the principle of light reflection, the Glossiness Meter evaluates the surface Gloss characteristics of a material by measuring the Glossiness value of the reflected light on its surface. Professional light path design ensures measurement Stability and accuracy.
Applications
Gloss measurement of inks, coatings, paint, paints, varnish and other surface Gloss measurement, building decoration materials: Stone, ceramics, ceramic tiles, marble, vitrified polished tiles and other surface Gloss measurement, printing, bamboo and wood products, fabrics, film paper, plastics and other surface Gloss measurement, rubber, leather, automobile maintenance and other surface Gloss measurement, other Non-metallic materials Surface Gloss measurement
Standards
ISO 2813、GB/T9754、ASTM D2457、ASTM D523、GB/T13891、GB/T7706、GB/T8807、JJG 696-2002
Steps
1. Turn on the instrument power.
2. Calibrate with standard black and white Calibration plate.
3. Place the probe on the surface of the tested item.
4. Press the measurement button for measurement.
5. Read and record measurement results.
Notice
• Operating temperature 15~ 40 ℃ and relative humidity < 85% without condensation environment
• Storage Temperature range -10 ℃~ 60 ℃
• Charging time 14~ 16 hours
• Calibration plate clean and free before measurement
• Avoid the probe scratching the surface of the tested item