Please contact customer service
Using IP65 Protection Rating, it can resist oil and dust corrosion; equipped with color LCD screen, clear display in dim or strong light; support multi-point calibrating, reduce measurement errors; automatically identify measurement direction, out of range alarm and voice broadcast.
Category : Leeb Hardness Tester
Brand : mitech
SKU : NB007827
Service :The delivery and service By NBCLab.Com
The MH600 Leeb hardness tester is an intelligent design instrument that is convenient for on-site metal hardness detection. It adopts IP65 Protection Rating, which can effectively resist harsh environments such as oil and dust. It is equipped with a color LCD screen, which can be clearly displayed in dim or strong light. It supports multi-point calibrating to reduce errors. It can automatically identify the measurement direction and support voice broadcast. It can perform a variety of hardness system conversions. It is powered by two AA batteries. The instrument is widely used in metal processing and manufacturing, special equipment failure analysis, commodity inspection and other fields, especially for on-site hardness testing of large non-removable parts.
1. Based on the Leeb hardness measurement principle, adapt to 6 kinds of Impact devices, automatically identify the type of device, and do not need to re-calibrate when replacing. 2. Automatic detection of Impact device status (connection, disconnection, failure, etc.). 3. Impact direction is automatically recognized (except G type), and 360 ° measurement is supported. 4. Adopt true color large screen 320 × 240 TFT LCD screen, adjustable luminance, adapt to different rays of light environment. 5. With basic single point calibrating and unique multi-point calibrating function, it can perform multi-point adjustment on the conversion Linear dispersion to reduce the error. 6. The measurement results can be freely converted between various hardness systems such as Richter (HL), Brinell (HB), Rockwell (HRB/HRC/HRA), Vickers (HV), and Shore (HS). 7. Built-in Richter hardness conversion function, support the mutual conversion between HLD value and HLC, HLG, HLDL, HLD + 15. 8. Can preset the upper and lower limits of hardness values, automatic alarm beyond the range, and support voice broadcast measurement results. 9. Support Chinese and English language switching, menu operation. 10. 500 sets of hardness measurement data can be stored, each set contains single measurement value, average value, date/time, Impact direction, number of times, material, hardness and other information. 11. Powered by two ordinary AA batteries, it can work continuously for not less than 100 hours, with power-saving functions such as automatic screen standby, hibernation, and shutdown. 12. Equipped with a USB interface, it can transfer data, perform storage management, statistical analysis, print reports, and set parameters in batches through PC software. 13. ABS engineering plastic sealing design, IP65 Protection Rating, effectively resist oil, dust and corrosion. 14.Compact dimensions (150mm × 76mm × 38mm), easy to carry.
The MH600 Leeb hardness tester works based on the Richter hardness measurement principle. The instrument uses the tungsten carbide ball head of the Impact device (e.g. D type) to impact the surface of the specimen with a certain energy (e.g. 11mJ), and measures the ratio of the rebound velocity of the Impact body to the Impact velocity at a distance of 1mm from the surface of the specimen. This value can be automatically converted to Miscellaneous hardness formats such as Brinell (HB), Rockwell (HRC/HRB/HRA), Vickers (HV), and Shore (HS) through the built-in conversion table to achieve fast and non-destructive hardness testing.
Mold cavities, bearings and other parts Pressure Vessel, turbo-generator sets and their equipment failure analysis, heavy workpieces installed machinery or permanent assembly parts, workpieces with very small test space, occasions requiring formal original records of test results, material distinction in metal material warehouses, rapid inspection of multiple measurement parts in a large range of large workpieces, in-service failure analysis of special equipment or permanent components, commodity inspection field
The data did not mention specific compliance criteria.
1. Install two AA AA batteries and turn on the instrument. 2. Select the appropriate Impact device (e.g. Type D) according to the tested material and connect it, and the instrument will automatically identify it. 3. Set the measurement parameters through the menu, such as material type (steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile cast iron, cast aluminum alloy, copper zinc alloy, copper tin alloy, pure copper, forged steel), hardness system, upper and lower limit alarm value, etc. 4. Press the Impact button to measure the impact device vertically or in the required direction against the surface of the test piece. 5. The instrument automatically recognizes the Impact direction and displays the hardness value (can be broadcast by voice). If it exceeds the preset range, it will automatically alarm. 6. Automatic storage of measurement data, can be connected to the computer through the USB interface, using supporting software for data transmission, management and report printing. 7. Turn off the power after use, or use the automatic sleep and shutdown functions to save power.
• Ensure that the average surface asperity of the specimen meets the requirements (e.g. D-type Impact device should be ≤ 1.6 μm). • The minimum depth of the hardened layer of the measured material must meet the requirements (such as D-type Impact device must be ≥ 0.8mm). • Impact device should be in stable contact with the specimen surface during measurement to avoid tilting or sliding. • Regularly use standard hardness blocks for calibrating, which can reduce errors by using single-point or multi-point calibrating function. • Avoid use in extreme temperature, humidity or strong electromagnetic interference environments to ensure measurement accuracy. • When replacing the Impact device, make sure the connection is firm and the instrument will automatically recognize it without recalibrating (except for Type G). • When the battery is low, replace it in time to avoid affecting the measurement accuracy or the normal operation of the instrument. • Keep the instrument clean, especially the ball head of the Impact device, to avoid oil and dust accumulation affecting the performance. When storing data, pay attention to the setting of groups and impact times (32 to 1), and manage 500 sets of storage space reasonably. When using PC-side software, ensure that the USB connection is stable and follow the software guidelines to avoid data loss.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.