The XIONGFA MH-600A Solid Density Meter is an economical digital display solid Density Meter with a Measurement range of 0.01g~ 600g and a density accuracy of 0.001g/cm3. It can directly read the density and volume of any shape with a density greater than or less than 1.
Features
1. Directly read the density and volume of any solid block, particle, floating body with a density > 1 or < 1
2. With temperature compensation setting and solution compensation setting functions, the operation is more user-friendly and meets the needs of on-site operations
3. Integrated injection molding of density measurement table, easy and fast installation, longer use time
4. Adopt integrated forming corrosion-resistant large sink design to reduce the buoyancy error of the hanging rail line and facilitate the testing of large objects
5. With density upper and lower limit function, can determine whether the specific gravity is qualified or not, with buzzer device
6. Built-in battery, with Draft Shield, more suitable for field testing
7. Optional liquid accessories can test liquid density and concentration
Principle
The Density Meter calculates density and volume by measuring the weight of solids in air and water. It has temperature compensation and solution compensation functions to ensure measurement accuracy.
Applications
Rubber, Plastic, Wires and cables, Electrical appliances, Sports equipment, Tires, Glass products, Carbide, Powder metallurgy, Magnetic materials, Seals, Ceramics, Sponge, EVA materials, Foam materials, Alloy materials, Friction materials, New materials research, Battery materials, Research laboratories
Standards
ASTM D792、ASTM D297、GB/T1033、GB/T2951、GB/T3850、GB/T533、HG4-1468、JIS K6268、ISO 2781、ISO 1183、ISO2781、ASTMD297-93、DIN 53479、D618、D891、ASTM D792-00、JISK6530、ASTM D792-00、JISK6530
Steps
1. Place the test object on the density measurement table
2. Set temperature compensation and solution compensation as needed
3. Start measurement, the device automatically calculates and displays density and volume results
4. Use the density upper and lower limit function to determine whether the specific gravity is qualified or not
Notice
• Ensure a stable measurement environment to avoid strong wind interference
• Correctly set temperature and solution compensation parameters
• Regularly check the battery power to ensure on-site test power supply
• Clean the sink after use to keep the equipment in good condition
• When selecting liquid accessories, it needs to be installed correctly.