Overview
The XIONGFA MDJ-300T Powder Density Meter is a measuring instrument that can accurately read the powder Density using the Archimide impregnation volume replacement method and the special Density Cup. The weighing range is 0.01-300 g, and the test results directly display the Density value.
Features
1. Directly read the Density of any powder or powder.
2. Simple operation, high accuracy and good repeability.
3. The temperature compensation setting and solution compensation setting can be carried out, and the operation is more user-friendly and more in line with the needs of on-site operations.
4. Density upper and lower limit determination function, can determine whether the specific gravity of the object to be tested is qualified or not, and a buzzer is provided.
5. With RS-232C computer interface, it can be connected to PCs and printers.
6. Built-in battery, with Draft Shield, more suitable for field testing.
Principle
The Density Meter uses Archimedes' immersion volume displacement method to calculate the Density value of the powder by measuring the weight of the powder in air and its buoyancy in a specific solution, combined with the volume of the dedicated Density Cup.
Applications
Vulcanized Rubber, Non-Foam, Carbon True Density, Rock, Coal True Density, Aspalt Coke Density, Ordinary Abrasive Density, Pigment Density, Solid and Semi-Solid Petroleum Aspalt Density, Pigment, Cement Powder, Fireproof Materials, Pottery and porcelain Materials, Natural Stone, Coal Water Slurry Density, Carbon Material True Density Boiling Method, Soil True Density Test Method, Ion Resin Wet True Density, Powder True Density Research Laboratory
Standards
GB/T533-A、GB/T1033.1、GB/T6155、GB/T23561、YB/T5300、JB/T7984.3、GB/T 1713、GB/T8929、GB/T1713、GB/T208、GB/T5071、QB/T1010、GB/T9966、GB/T18856、GB/T24203、GB/T8330、SL-237
Steps
1. Place the sample in a Density Cup.
2. Place the Density Cup on the measurement table for weight measurement in the air.
3. Add replacement liquid to the Density Cup for liquid weight measurement.
4. The instrument automatically calculates and displays the Density value.
Notice
Please ensure that the instrument is placed horizontally before use.
Select the appropriate replacement liquid according to the sample characteristics.
* The temperature compensation setting is required before measurement to ensure accuracy.
* Keep Density Cup and sample clean and drying to avoid contamination affecting results.
Regularly calibrate and maintain instruments.
* Do not use in a strong electromagnetic interference environment.
The built-in battery needs to be charged regularly to ensure on-site use.
* Use Draft Shield to reduce the impact of airflow on measurement.