The device is an integrated design of viscosity and temperature control, using a small sample adapter and SC4 rotor, the sample dosage is only 2-16ml, the temperature control accuracy can reach +/- 0.1 ℃, and supports rheological Linear dispersion analysis.
Category : Rotational Viscometer
Brand : NiRun
SKU : NB008860
Service :The delivery and service By NBCLab.Com
The NIRUN RDV-T2 digital Viscometer is an all-in-one viscosity and temperature control device that integrates viscosity measurement and precise temperature control. It uses a Small Sample Adapter (SSR) system consisting of a sample sleeve and an SC4 rotor. It requires only 2-16ml of samples to make accurate measurements at specific shear rates. Its cylindrical geometry ensures the accuracy of viscosity data and shear rates. The all-in-one design simplifies the complex structure of traditional split systems (thermostatic sink, Viscometer, adapter). The sample cartridge is easily loaded and cleaned, and it is tightly connected to the thermostat. Combined with the rotor Stir and a small number of samples, it can quickly even the sample temperature and significantly reduce the thermostatic time. The device achieves precise temperature control (accuracy +/- 0.1 ° C) through semiconductor temperature control and built-in optimization program, and the lifting temperature is adjustable, which facilitates the study of sample performance through temperature changes. Viscosity measurement is operated by DV-T2 data collection and programmable analysis software, which supports rheological Linear dispersion analysis, improving experimental accuracy and operational flexibility.
1 viscosity temperature control machine design, integrated measurement and temperature control, simplify the experimental setup. 2. Using a small sample adapter (SSR) system, the sample dosage is only 2-16ml. 3. SC4 rotor cylindrical structure provides accurate viscosity measurement and shear rate data. 4. The sample cylinder is easy to load, unload and clean, and is tightly connected to the thermostat for accurate temperature control. 5. Stir the rotor with a small amount of samples to reduce temperature inhomogeneity and shorten the thermostatic time. 6. Temperature control using semiconductor and automatic optimization program, temperature control accuracy of +/- 0.1 ℃, rising/cooling adjustable. 7. Operated by DV-T2 software, support data collection, programmable analysis and rheological Linear dispersion analysis. 8. Provide a variety of optional rotor models to adapt to different measurement needs. 9. Adopt metal lifting system, ruby bearing, beryllium bronze torque material and microcomputer control system. 10. Continuously variable speed regulation, speed range 0.1~ 200rpm.
The RDV-T2 digital Viscometer works on the principle of swirl/spin viscosity measurement. The instrument drives the SC4 rotor to swirl/spin in a small sample sleeve filled with samples. The viscosity of the sample is calculated by measuring the torque subjected to the rotor swirl/spin in the fluid. The process is carried out at a certain shear rate, and the cylindrical geometry ensures the accuracy of the shear rate. At the same time, the integrated temperature control system precisely heats or chills down the sample sleeve through semiconductor elements and a built-in optimization program. The sample temperature is controlled within the set range (-1 ° C to 150 ° C) with an accuracy of +/- 0.1 ° C. Stir action of the rotor combined with a small amount of samples accelerates heat transfer and makes the sample temperature uniform quickly. The measurement data can be processed by a microcomputer control system, and can be collected, programmed and analyzed by DV-T2 software.
Petrochemicals, Paint inks, Adhesives, Food and Beverage, Cosmetics, Pharmaceuticals, Research and Education
The data did not mention specific compliance criteria
Install the equipment and connect the power supply (AC100-240V). 2. Select the appropriate SC4 rotor according to the measurement requirements and install it. 3. Inject 2-16 ml of sample into the Small Sample Adapter (SSR) sleeve. 4. Install the sample sleeve onto the instrument to ensure a tight connection to the temperature controller. 5. Set the required measurement temperature (-1 ℃~ 150 ℃) and Rotor speed (0.1~ 200rpm) through the instrument panel or DV-T2 software. 6. Start the temperature control program and wait for the sample to reach the set temperature and stabilize. 7. Start the viscosity measurement program, the instrument starts swirling/spinning the rotor and measuring torque. 8. Real-time collection of viscosity data through DV-T2 software, and rheological Linear dispersion analysis. 9. After the measurement is complete, turn off the instrument and remove the sample sleeve and rotor for cleaning.
Please use a power supply that meets the specifications (AC100-240V, 50/60Hz or DC17V 1.2A). * When selecting the rotor model and setting the speed, ensure that the measurement value is within the instrument range (25~ 10,000,000 mPa · s). * The sample volume should be controlled within the range of 2-16ml to ensure the measurement and temperature control effect. When loading and unloading sample sleeves and rotors, be careful to avoid damage. * When cleaning the sample sleeve and rotor, use a suitable solvent and ensure thorough drying. The temperature setting must not exceed the range of -1 ° C to 150 ° C. * Make sure that the sample sleeve is tightly connected to the temperature control part to ensure the temperature control accuracy. When using DV-T2 software, ensure that the computer and instrument are connected correctly through the RS232 interface. * The instrument should be placed on a stable working table to avoid vibration interference measurement. Regularly check components such as the bearing system to ensure that the instrument is in good working condition.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.