Overview
YIHENG LHS-100CH Constant Temperature and Humidity Chamber adopts equilibrate control, Humidity Control Range is 80~ 95% RH, input Power is 1650W, with accurate temperature and Humidity Control system, Temperature resolution and Humidity deviation are 0.1 ℃、 +/- 3% RH respectively. This product provides various simulated environmental conditions required for industrial research and biotechnology testing.
Features
1. Adopt a new fluorine-free design.
2. Mirror stainless steel liner, four corners and half arcs are easy to clean, and the shelf spacing in the box is adjustable.
3. Microcomputer Temperature Humidity Controller, using TMHM equilibrate Conditioning method, stable operation, accurate temperature and humidity control and safe and reliable, controller, Compressor and other key components are imported products.
4. It is equipped with an independent temperature limit alarm system, which automatically interrupts when the temperature exceeds the limit to ensure the safe operation of the experiment.
There is a 25mm diameter test hole on the left side of the box, which is convenient for experimental operation and Measuring temperature.
6. Can be equipped with recorder to record temperature and Humidity Linear dispersion (optional).
Principle
Microcomputer Temperature Humidity Controller and TMHM equilibrate Conditioning method are adopted to ensure stable operation and accurate and reliable temperature and humidity control through precise control of temperature and Humidity.
Applications
Industrial Research, Biotechnology Testing, Spinning & Weaving, Food processing and other aseptic testing, Stability inspection, Raw material performance testing of industrial products, Product Encasement testing, Product life testing
Steps
1. Connect the power supply to AC220V50HZ (LHS-100CB is AV380V50HZ).
2. Set the required temperature and Humidity parameters through the microcomputer temperature and Humidity controller.
3. Place the sample on the shelf with adjustable spacing.
4. Use the test hole on the left side of the box for experimental operation and temperature measurement.
5. Optional recorder to record Humidity Linear dispersion.
6. After the experiment is completed, turn off the power and clean the cabinet.
Notice
• Ambient Temperature should be maintained at 5~ 30 ℃.
• When the temperature limit is exceeded, the independent temperature limit alarm system will automatically interrupt the operation to ensure safety.
• Power supply voltage is checked before use (AC220V50HZ or AV380V50HZ).
• Regularly clean the mirror stainless steel liner to maintain hygiene.
• The recorder is an optional accessory and requires additional configuration.
• Net weight 118Kg, be careful when handling.