Overview
YIHENG LHS-100CB Constant Temperature and Humidity Chamber Temperature range is -40~ 85 ℃, Humidity Control Range is 45~ 95% RH. The equipment contains a refrigeration system, which needs to dissipate heat during operation, and the Operating Environment must not exceed 27 ℃ room temperature. The Constant Temperature and Humidity Chamber has a precise temperature and Humidity Control system, which can provide various simulated environmental conditions required for industrial research and biotechnology testing.
Features
1. Adopt fluoride-free design, in line with the concept of healthy living
2. Mirror stainless steel liner, four corners and half arcs are easy to clean, and the shelf spacing in the box is adjustable
3. Microcomputer Temperature and Humidity Controller, using TMHM equilibrating Conditioning method, stable operation, accurate and reliable temperature and humidity control, key components are imported products
4. Equipped with an independent temperature limit alarm system, which automatically interrupts when the temperature exceeds the limit to ensure the safety of the experiment
5. There is a 25mm diameter test hole on the left side of the box, which is convenient for experimental operation and Measuring temperature
6. Optional recorder, Record Temperature Humidity Linear dispersion
Principle
The Constant Temperature and Humidity Chamber adopts the TMHM equilibrated Conditioning method through the microcomputer temperature and Humidity controller to achieve accurate temperature and Humidity control. The equipment contains a refrigeration system, which needs to dissipate heat during the working process to ensure a stable environment in the box.
Applications
Spinning & weaving, Food processing and other aseptic tests, Stability inspection, Raw material performance testing of industrial products, Encasement testing, product life testing
Steps
1. Ensure that the Working Ambient Temperature does not exceed 27 ℃
2. Connect the power supply (AC220V50HZ or AV380V50HZ)
3. Set Required Temperature and Humidity Parameters
4. Place the test sample on the shelf
5. Start the device running
6. Experimental operation and temperature measurement can be carried out through the left test hole
7. Optional recorder to record running Linear dispersion
Notice
• Operating Environment shall not be higher than 27 ℃ room temperature environment
• Working ambient temperature range is 5~ 30 ℃
• The equipment contains a refrigeration system, which requires heat dissipation during operation
• When the temperature limit is exceeded, the independent temperature limit alarm system will automatically interrupt the operation
• Power supply voltage: LHS-100CB is AV380V 50HZ
• Net weight of the equipment 279Kg, pay attention to safety when handling