Please contact customer service
Sensor with thermal conductivity principle, detection accuracy +/- 3% F.S., Response Time T90 ≤ 20s. Support -40~ + 70 ℃ wide temperature work, with infrared remote control, a variety of communication interfaces and data recovery functions, suitable for harsh industrial environments.
Category : Gas Detector
Brand : GaoPin
SKU : NB009274
Service :The delivery and service By NBCLab.Com
The GAOPIN NGP5-N2-A Fixed Nitrogen Alarm Instrument is an online nitrogen Gas detector for 24-hour continuous on-line monitoring of gas concentration in the field. The instrument uses a thermal conductivity principle Sensor, equipped with a 1.7-inch high definition color screen to display on-site concentration, and supports on-site sound and light alarm (optional) and remote signal transmission. The rugged explosion-proof housing is suitable for various hazardous locations and harsh industrial environments.
1. Units can be switched freely. 2. Diversified communication methods: real-time monitoring can be carried out through wired or wireless remote transmission and network transmission; support three-wire 4~ 20mA standard signal and standard bus RS485 (modbus-RTU) simultaneous output; optional frequency output 200-1000Hz, Hart protocol signal, 1~ 5V output, two-wire 4~ 20mA, SMS alarm, wireless transmission (2~ 5 kilometers or unlimited distance); compatible with secondary instruments, data collection modules, PLC, DCS systems. 3. Infrared remote control: Standard infrared remote control, which can be operated without opening the lid in dangerous situations, such as modifying the alarm point, concentration calibrating, zero point calibrating, muffling, and restoring the factory. 4. Rich man-machine interface: 1.7-inch high definition color screen, showing real-time concentration and alarm status. 5. High temperature Gas detection (optional): Optional high temperature and high humidity pretreatment system can detect high temperature flue gas. 6. Data recovery function, in case of wrong operation, you can choose partial or full recovery. 7. You can set whether to display MAX Maximum and MIN Minimum. 8. Various alarm methods: including 2 sets of relay switch output, sound and light alarm (optional), display visual alarm. Alarm types include concentration alarm and fault alarm. 9. Multiple alarm mode settings: low alarm, high alarm, interval alarm, weighted average alarm. 10. Misoperation identification function: concentration calibrated misoperation automatic identification and prevention. 11. Zero automatic tracking, long-term use is not affected by zero drift. 12. Target point multi-level calibrated to ensure Linearity and accuracy of measurement. 13. Chinese or English interface is optional. 14. operating temperature: -40~ + 70 ℃, support temperature compensation. 15. Logging: record calibrating logs, maintenance logs, fault records, fault solutions, Sensor life expiration reminders, next concentration calibrating time reminders. 16. Intrinsically safe circuit design, explosion-proof, with secondary lightning protection and anti-static capabilities. Meet national standards, resist high-intensity pulse surge current Impact. With anti-reverse connection function. Comply with EMI and CEMC standards.
The instrument adopts the principle of thermal conductivity Sensor to detect nitrogen concentration. The Sensor converts the gas concentration signal into an electrical signal, and displays the concentration value in real time on the display screen after processing, and outputs the signal or triggers the alarm through various communication methods.
Petroleum, chemical, metallurgy, refining, gas transmission and distribution, biochemical and other industries
EMI, CEMC standard, explosion-proof mark: Exia II CT6, certificate number: CNEx15.1283
1. Installation and fixation: Choose Wall-Mounted or pipeline installation according to the site conditions. Connect the power supply and signal line: Connect a 12-30VDC DC power supply (standard 24V), and connect the corresponding cable according to the output signal type (e.g. 4-20mA or RS485). 3. Boot and initialization: Power on, the instrument starts and performs self-test. 4. Parameter settings: Use the standard infrared remote control or through the Miscellaneous compatible system to set parameters such as alarm points, units, and display modes. 5. Calibrating operation: In a safe environment, use the infrared remote control for zero-point calibrating or concentration calibrating. The instrument has the function of misoperation identification. 6. Operation monitoring: The instrument starts continuous online monitoring, and the real-time concentration is displayed on the 1.7-inch color screen. 7. Alarm processing: When the concentration exceeds the standard, the instrument will trigger the set alarm mode (such as relay output, sound and light alarm, etc.). 8. Data viewing and maintenance: Data, alarm records and instrument logs can be viewed through the display screen or remote monitoring center, and regular maintenance or Sensor replacement can be performed according to the log reminder.
● When installing, ensure that the sampling method (diffusion, pipeline, flow or pump suction) is suitable for the on-site environment. When connecting the cable, it is recommended to use a three-core Shielding cable for 4 to 20mA output, and a four-core cable for RS485 output; when the transmission distance exceeds 1000 meters, the single wire diameter should be ≥ 1.5mm, and the Shielding layer needs to be grounded. The power supply needs to use a DC regulated switching power supply, and the standard power supply for a single device is 24V, 1A or greater than 1A. The instrument is explosion-proof, but the installation and operation still need to comply with the safety regulations of the relevant dangerous places. When calibrating, ensure that it is operated in a safe and calibrated environment to avoid misoperation. ● Optional functions (such as wireless transmission, high temperature detection, sound and light alarm, etc.) should be clear when booking. ● Instrument working environment humidity range is ≤ 10~ 95% RH, built-in Filter can be used in high humidity or high dust environment, but still need to pay attention to the impact of environmental conditions on long-term stability. ● Sensor life is about 2 to 3 years, need to pay attention to the instrument log life expiration reminder and timely replacement. ● Ensure that the Instrument Protection Rating (IP65) meets the installation environment requirements.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.