Please contact customer service
Can simultaneously detect four gases, built-in pump sampling and integrated Filter, suitable for high humidity and high dust environment, sampling distance is greater than 10 Meters, support -40 ℃~ + 70 ℃ wide temperature work, with sound and light vibration alarm and 100,000 data storage.
Category : Gas Detector
Brand : GaoPin
SKU : NB009281
Service :The delivery and service By NBCLab.Com
The GAOPIN NGP40-M400 Portable multifunctional 4-in-1 Gas detector is a professional device for the simultaneous rapid detection of carbon monoxide (CO), hydrogen sulfide (H2S), oxygen (O2) and combustible gas concentrations, as well as the measurement of environment temperature and humidity. When the measurement value exceeds the preset limit, the instrument will sound and light vibration alarm. The product features a 2.31 inch high definition color screen display, built-in pump suction sampling system, suitable for gas concentration detection in pipelines, confined spaces, atmospheric environments, and high concentration single gas purity analysis. It can detect more than 500 gas types.
1. It can simultaneously detect the concentration of CO, H2S, O2 and combustible gas. 2. Built-in pump suction measurement, integrated water vapor and dust Filter, suitable for high humidity and high dust environment; special gas path design, sampling distance greater than 10 meters, can directly detect negative or positive pressure gas. 3. Equipped with 2.31 inch high definition color screen, rich display information, menu interface using high definition simulation graphics. 4. With large-capacity data storage function (standard 100,000), it supports a variety of storage and viewing methods. 5. Optional high temperature sampling components can detect high temperature flue gas (such as 400 ° C). 6. Support three display modes to switch: four-gas simultaneous display, single-channel large font loop display, real-time Linear dispersion display. 7. With data recovery, graphical concentration Linear dispersion, a variety of numerical display modes (maximum, minimum, average) and other functions. 8. Using 4500mAh large-capacity polymer battery, support USB charging and work. 9. Provide a variety of alarm methods (sound, light, vibration, vision) and alarm modes (low, high, interval, weighted average alarm). 10. With error recognition, zero point automatic tracking, target point multi-level calibrating, Chinese and English interface, wide temperature working (-40 ℃~ + 70 ℃) and logging and other functions. 11. Meet the intrinsically safe circuit design, Protection Rating up to IP65, with explosion-proof, shockproof and other characteristics.
The gas detector uses a Sensor based on electrochemistry and catalytic combustion principles to detect the target gas. The built-in sampling pump sucks the environment gas. After an integrated water vapor and dust filter, the gas reacts with the Sensor to generate an electrical signal related to the gas concentration. Professional circuit design and kernel algorithms process these signals, and finally display the gas concentration value on the screen in real time and alarm according to the settings.
Gas detection, confined space operation, atmospheric environment monitoring, gas leakage detection, high concentration single gas purity analysis
Exia Ⅱ CT6
1. Turn it on to check the power and status of the equipment. 2. Select the detection mode (real-time detection or timing detection) as needed. 3. Use the sampling pump to suck the gas to be measured into the instrument. 4. Real-time observation of gas concentration, temperature and humidity data and changes through a 2.31-inch color screen Linear dispersion. 5. During the detection process, if the gas concentration exceeds the limit, the instrument will alarm in a preset manner. 6. The detection data is automatically stored, and the analysis can be exported through the local viewing or USB interface. 7. Turn off after use and charge if necessary.
Do not use in an environment beyond the specified temperature, humidity and pressure range. • Avoid strong impact or long-term immersion in water. • When using in high dust or high humidity environments, ensure that the Filter is effective and maintained regularly. • When performing concentration calibrating, please follow the procedures. The instrument has the function of misoperation identification. Sensor life (electrochemistry 2-3 years, catalytic combustion 3 years), timely replacement. • Please use a matching or standard USB charging device when charging. When the instrument alarms, please take appropriate measures immediately according to the safety procedures. • When selecting a high temperature sampling handle, confirm that the flue gas temperature to be measured is within the allowable range.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.