Overview
SMART SENSOR AK390 is a mini Infrared Thermometer with high cost performance, simple and practical characteristics. Its temperature measurement range is -32~ 390 ℃, using infrared non-contact temperature measurement method, suitable for rapid temperature measurement in various scenarios.
Features
1. Mini portable design, weight only 130g, small size.
The temperature measurement range is wide, covering from -32 ° C to 390 ° C.
3. Fast Response, Response Time is 500ms.
4. The object distance ratio is 12:1, which can be measured at a certain distance.
5. Blister Encasement, easy to carry and store.
Principle
The Infrared Thermometer works on the principle of infrared radiation temperature measurement. All objects emit infrared radiation, and its radiation energy is related to the surface temperature of the object. The instrument receives infrared radiation with a wavelength of 8 to 14 μm emitted by the target object through the Sensor, converts it into an electrical signal, and displays the corresponding temperature value on the display screen after processing.
Applications
Industrial equipment inspection, electrical equipment inspection, automobile maintenance, HVAC system inspection, Food processing temperature monitoring, daily life temperature measurement
Standards
The data did not mention specific compliance criteria.
Steps
Load two 1.5V AAA batteries.
2. Press the power button to start the device.
3. Align the thermometer to the surface of the object to be measured.
4. Ensure that the measurement distance meets the 12:1 object distance ratio requirements.
5. Press the measurement button to measure the temperature.
6. Read the temperature value displayed on the display.
Notice
• When measuring, please note that the emissivity is set to 0.95 (fixed), and the reading may not be accurate when measuring smooth or reflective surfaces.
• The measurement accuracy is +/- 2% or +/- 1 ° C (maximum), and the repeability is +/- 1 ° C or +/- 1%.
• Do not point the laser directly at the eye or indirectly into the eye through the reflection surface.
• This device is used for measurement of surface temperature and cannot measure the internal temperature of objects.
• Avoid use in environments with extreme temperatures, excessive dust or strong electromagnetic interference.
• When not in use for a long time, please remove the battery.