Overview
The SMART SENSOR AR380 is a mini Infrared Thermometer with a non-contact temperature measurement method, with a measurement range of -50 ° C to 380 ° C, with fast Response and high portability. The product design is compact and lightweight, easy to carry and operate, suitable for temperature measurement needs in a variety of scenarios.
Features
1. Wide measurement range: -50 ℃ to 380 ℃.
High accuracy: +/- 2% or +/- 2 ° C (whichever is greater).
3. High resolution: 0.1 ℃.
4. Response speed: 500ms.
5. The object distance ratio is large: 12:1, which can be accurately measured at a certain distance.
6. Fixed emissivity: 0.95, suitable for most material surfaces.
7. Portable design: mini size (146 * 80 * 38mm), light weight (130g).
8. Convenient power supply: Powered by 2 1.5V AAA batteries.
Principle
The Infrared Thermometer works on the principle of infrared radiation temperature measurement. All objects emit infrared radiation, and its intensity is related to the surface temperature of the object. The instrument collects the infrared radiation energy emitted by the target object (Response wavelength is 8~ 14 μm) through the Optical inspection system and focuses it on the infrared detector. The detector converts the radiation energy into an electrical signal, and after signal processing and algorithm calculation, the surface temperature value of the measured object is finally displayed on the display screen.
Applications
Industrial equipment inspection, electrical maintenance, automobile maintenance, HVAC system inspection, Food processing temperature monitoring, scientific research experiments, daily use at home
Standards
The information does not mention
Steps
Load two 1.5V AAA batteries.
2. Press the power button to start the device.
3. Align the thermometer to the surface of the object to be measured.
4. Ensure that the measurement distance meets the 12:1 object distance ratio requirements.
5. Press the measurement button to measure the temperature.
6. Read the temperature value displayed on the display.
7. After use, press the power button again to turn off the device.
Notice
* This instrument measures the surface temperature of the object, not the internal temperature.
* When measuring, make sure that the laser point is aligned with the target area and pay attention to the object distance ratio (12:1).
* Avoid measurement of bright or polished metal surfaces, which may affect accuracy.
* Steam, dust, smoke, etc. in the environment may interfere with measurement results.
* Fixed emissivity 0.95, for special materials with large emissivity differences, the measurement may need to be corrected.
* Do not aim the laser directly at the eye or indirectly into the eye through the reflection surface.
When not in use for a long time, please remove the battery.
* This product is a measurement tool and does not have safety protection functions. Do not use it in a dangerous environment instead of professional safety equipment.