Overview
SMART SENSOR AS320 Mini Infrared Thermometer is a cost-effective, simple and practical temperature measurement device. It uses infrared temperature measurement technology to quickly measure the surface temperature of objects and is suitable for a variety of non-contact temperature measurement scenarios.
Features
1. Mini portable design, size is 143 * 93 * 38mm, weight is only 150g, easy to carry.
The temperature measurement range is wide, covering from -32 ° C to 380 ° C.
3. High measurement accuracy, Accuracy of +/- 2%, resolution of 0.1 ℃.
4. Fast Response, Response Time is only 500ms.
5. Using the object distance ratio of 12:1, accurate measurement can be made at a certain distance.
6. Powered by two AAA batteries, the battery life is convenient.
Principle
The Infrared Thermometer works on the principle of infrared radiation. All objects emit infrared radiation, the intensity of which is related to the surface temperature of the object. The instrument receives infrared radiation with a wavelength of 8 to 14 μm emitted by the target object through the Sensor, converts it into an electrical signal, and displays the corresponding temperature value on the display screen after processing.
Applications
Industrial maintenance, electrical inspection, automotive repair, HVAC (heating, ventilating and air conditioning), Food processing, household daily use
Standards
The data did not mention specific compliance criteria.
Steps
Install two AAA batteries.
2. Turn on the power switch of the device.
3. Aim the laser aiming point at the surface of the object to be measured.
4. Maintain the appropriate measurement distance (according to the object distance ratio of 12:1).
5. Press the measurement button to measure the temperature.
6. Read the temperature value displayed on the display.
Notice
• This instrument measures the surface temperature of the object, not the internal temperature.
• Ensure that the measurement path is clean and free of steam, dust and other disturbances.
• When measuring bright metal surfaces, the reading may be inaccurate. It is recommended to use tape or matte paint to treat the surface before testing.
• Avoid aiming the laser directly at the eye or indirectly irradiating the eye through the reflection surface.
Do not use this equipment in extremely hot or humid environments.
• When not in use for a long time, please remove the battery.
• The instrument accuracy is +/- 2%, the repeability is +/- 1 ° C or +/- 1%, please pay attention to the measurement error.