| Product Name | Bante Bante902P-CN Portable Multi-ParaMeter water quality measurement instrument | HANNA HI8424 Acidity Meter |
| Product Price | In coming | $706.00 |
| Details | Details | |
| Model comparison | ||
| Type | Multiparameter | Multiparameter |
| Style | Portable | Portable |
| Detection Principle | Electrode | Electrode |
| Measurement parameters | pH EC TDS ORP Salinity Temperature | pH ORP Temperature |
| Range | Wide Range | Wide Range |
| Accuracy | ±1%FS | ±0.5%FS |
| Resolution | 1 | 1 |
| Data Output | USB | |
| IP Rating | IP57 | |
| Parameter comparison | ||
| Measurement Range of pH | -2.000~20.000pH | |
| Measurement accuracy of pH | ±0.002pH | |
| pH resolution | 0.1, 0.01, 0.001 pH, optional | |
| pH calibrating point | 1 to 5 points | |
| pH calibrating solution | USA, NIST, DIN, Custom | |
| pH temperature compensation Range | 0~100℃, 32~212℉ | Automatic or manual temperature compensation in the Range of -20.0 - 120.0 ° C/-4.0 - 248.0 ° F (without temperature sensor) |
| pH temperature compensation | Manual/Automatic | |
| ORP Measurement Range | ±1999.9mV | ±699.9mV;±1999mV |
| mV Measurement accuracy | ±0.2mV | |
| mV resolution | 0.1, 1mV, optional | |
| mV calibrated point | 1 point (for R.mV mode only) | |
| mV calibrated Range | ±200mV | |
| Measurement Range of conductivity | 0~ 20mS/cm (max 200mS/cm) | |
| Measurement accuracy of conductivity | ±0.5%FS | |
| Conductivity resolution | 0.001, 0.01, 0.1, 1 | |
| Conductivity calibrating point | 1 to 5 points | |
| Conductivity calibrating fluid | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm | |
| Conductivity temperature compensation Range | 0~100℃, 32~212℉ | |
| Conductivity temperature compensation | Manual or automatic | |
| Conductivity temperature compensation coefficient | 0.0~10.0%/℃ | |
| Conductivity temperature compensation mode | Linear or pure water | |
| Conductivity detector cell constant | K = 0.1, 1, 10, custom | |
| Standardized temperature | 20℃, 25 ℃, optional | |
| TDS Measurement Range | 0~ 10ppt (max 200ppt) | |
| TDS Measurement accuracy | ±1%FS | |
| TDS conversion factor | 0.1~ 1.0 (default 0.5) | |
| Measurement Range of salinity | 0~ 10ppt (max 80ppt) | |
| Measurement accuracy of salinity | ±1%FS | |
| Measurement mode of salinity | Utility salinity (psu) or seawater salinity (ppt) | |
| Measurement Range of resistivity | 0~ 10MΩ (up to 20MΩ) | |
| Measurement accuracy of resistivity | ±1%FS | |
| Resistivity resolution | 0.01, 0.1, 1 | |
| Measurement Range | 0~105℃, 32~221℉ | |
| Measurement accuracy | ±0.5℃ | ±0.4℃/±0.8℉ |
| Temperature resolution | 0.1℃ | 0.1℃/0.1℉ |
| Temperature calibrated mode | 1 point | |
| Temperature unit | ° C, ° F, optional | |
| Calibrated reminder | 1 to 31 days or closed | |
| shutdown mode | Manual or automatic (10, 20, 30 minutes after no button operation) | |
| Data storage | 500 sets | |
| Communication interface | USB | |
| connector | BNC, 6-pin MINI connector | |
| power supply | 3 AA batteries | |
| Battery life | Approximately 150 hours (when the LCD backlight is turned off) | 9V high-performance battery, 150 hours of continuous operation |
| Dimension | 170*85*30mm | |
| instrument weight | 300g | |
| Optional Accessories | P11 Type pH Electrode, P11-LiCl Type pH Electrode, P11-HA Type pH Electrode, P11-NA Type pH Electrode, P12 Type pH Electrode, P13 Type pH Electrode, P15 Type pH Electrode, P16 Type pH Electrode, P18 Type pH Electrode, P19 Type pH Electrode, P21 Type pH Electrode, P22 Type pH Electrode, 501 Type ORP Electrode, 502 Type ORP Electrode, CON - 0.1 Type Conductivity detector Electrode, CON - 1 Type Conductivity detector Electrode, Con-10 Type Conductivity detector Electrode, Conductivity detector standard solution, TP - 10K temperature probe, pH standard buffer Reagent (USA Standard), pH Standard Buffer Reagent (NIST Standard) | |
| Packaging Dimensions | 340*290*80mm | |
| Encasement weight | 1.5kg | |