| Product Name | Bante Bante902P-UK Portable Multi-ParaMeter water quality measurement instrument | Bante PE-10 Dual channel pen instrument |
| Product Price | $593.00 | In coming |
| Details | Details | |
| Model comparison | ||
| Type | Multiparameter | Multiparameter |
| Style | Portable | Pen style |
| Detection Principle | Electrochemical Electrode Conductivity | Electrode Conductivity |
| Measurement parameters | pH EC TDS ORP Salinity Temperature | pH EC Temperature |
| Range | Wide Range | Wide Range |
| Accuracy | ±1%FS | ±1%FS |
| Resolution | 1 | 1 |
| Data Output | USB | |
| IP Rating | ||
| Parameter comparison | ||
| Measurement Range of pH | -2.000~20.000pH | |
| Measurement accuracy of pH | ±0.002pH | |
| pH resolution | 0.1, 0.01, 0.001 pH, optional | |
| pH calibrating point | 1 to 5 points | |
| pH calibrating solution | USA, NIST, DIN, Custom | |
| pH temperature compensation Range | 0~100℃, 32~212℉ | |
| pH temperature compensation | Manual/Automatic | |
| ORP Measurement Range | ±1999.9mV | |
| mV Measurement accuracy | ±0.2mV | |
| mV resolution | 0.1, 1mV, optional | |
| mV calibrated point | 1 point (for R.mV mode only) | |
| mV calibrated Range | ±200mV | |
| Measurement Range of conductivity | 0~ 20mS/cm (max 200mS/cm) | 0~20.00, 200.0, 2000 µS/cm, 20.00 mS/cm |
| Measurement accuracy of conductivity | ±0.5%FS | Full scale +/- 1% |
| Conductivity resolution | 0.001, 0.01, 0.1, 1 | |
| Conductivity calibrating point | 1 to 5 points | 1~ 3 points |
| Conductivity calibrating fluid | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm | |
| Conductivity temperature compensation Range | 0~100℃, 32~212℉ | |
| Conductivity temperature compensation | Manual or automatic | |
| Conductivity temperature compensation coefficient | 0.0~10.0%/℃ | |
| Conductivity temperature compensation mode | Linear or pure water | |
| Conductivity detector cell constant | K = 0.1, 1, 10, custom | |
| Standardized temperature | 20℃, 25 ℃, optional | |
| TDS Measurement Range | 0~ 10ppt (max 200ppt) | |
| TDS Measurement accuracy | ±1%FS | |
| TDS conversion factor | 0.1~ 1.0 (default 0.5) | |
| Measurement Range of salinity | 0~ 10ppt (max 80ppt) | |
| Measurement accuracy of salinity | ±1%FS | |
| Measurement mode of salinity | Utility salinity (psu) or seawater salinity (ppt) | |
| Measurement Range of resistivity | 0~ 10MΩ (up to 20MΩ) | |
| Measurement accuracy of resistivity | ±1%FS | |
| Resistivity resolution | 0.01, 0.1, 1 | |
| Measurement Range | 0~105℃, 32~221℉ | PH: Measurement Range EC: 0~ 60 ° C/32~ 140 ° F |
| Measurement accuracy | ±0.5℃ | ±1℃/±1.8℉ |
| Temperature resolution | 0.1℃ | |
| Temperature calibrated mode | 1 point | |
| Temperature unit | ° C, ° F, optional | |
| Calibrated reminder | 1 to 31 days or closed | |
| shutdown mode | Manual or automatic (10, 20, 30 minutes after no button operation) | |
| Data storage | 500 sets | |
| Communication interface | USB | |
| connector | BNC, 6-pin MINI connector | |
| power supply | 3 AA batteries | |
| Battery life | Approximately 150 hours (when the LCD backlight is turned off) | |
| Dimension | 170*85*30mm | |
| instrument weight | 300g | |
| Optional Accessories | P11 Type pH Electrode, P11-LiCl Type pH Electrode, P11-HA Type pH Electrode, P11-NA Type pH Electrode, P12 Type pH Electrode, P13 Type pH Electrode, P15 Type pH Electrode, P16 Type pH Electrode, P18 Type pH Electrode, P19 Type pH Electrode, P21 Type pH Electrode, P22 Type pH Electrode, 501 Type ORP Electrode, 502 Type ORP Electrode, CON - 0.1 Type Conductivity detector Electrode, CON - 1 Type Conductivity detector Electrode, Con-10 Type Conductivity detector Electrode, Conductivity detector standard solution, TP - 10K temperature probe, pH standard buffer Reagent (USA Standard), pH Standard Buffer Reagent (NIST Standard) | |
| Packaging Dimensions | 340*290*80mm | |
| Encasement weight | 1.5kg | |