| Product Name | DongRu DR360 Coating thickness Gauge | Leeb leeb242(F1) Coating thickness Gauge |
| Product Price | $364.00 | $525.00 |
| Details | Details | |
| Model comparison | ||
| Principle | Difunctional | Magnetic |
| Substrate | Ferrous Non-Ferrous | Ferrous |
| Range | 0 ~ 1500m | 0 ~ 1500m |
| Precision | ±1% ±2% ±3% | ±3% |
| Probe | Split probe | Split probe |
| Application | General | General |
| Accessories | ||
| Parameter comparison | ||
| Measurement principle | Magnetic Induction + eddy Current | |
| Measurement Range | 0~1250μm | 0~1250μm |
| margin of error | ±(1%-3%)H+1.5μm | |
| resolution | 0.1 μm /1 μm (0.1 μm below 100 μm, 1 μm above 100 μm) | |
| minimum radius of curvature | Convex 5mm; Concave 25mm | Convex 1.5, concave 9mm |
| thinnest matrix | 0.3mm | |
| Probe | F and N Split Probes | |
| statistical function | Average, MAX Maximum, MIN minimum, Number of Tests | |
| icon function | without | |
| power supply | Three (7) alkaline batteries | 6V/600mA rechargeable nickel-metal hydride battery |
| Meet the standard | GB/T 4956-1985 | |
| Calibrated certificate | without | |
| system language | Chinese, English | |
| display screen | 2.3-Inch large color screen with large font Size display | |
| companion software | without | |
| Machine weight | 100g | |
| Machine Size | 130*70*25mm | |
| minimum measurement surface | Φ11.5mm | |
| Operating Environment | Temperature: 0℃ -60℃, Humidity: 20% RH - 90% RH, no strong magnetic field environment | |
| unit display | μm/Mil | |
| shutdown mode | Manual/Automatic | |
| Data storage | It can be stored in 10 groups, 200 in each group, and a Total of 2000 data can be stored | |
| Calibrated mode | Zero point calibrated, two point calibrated, multi point calibrated | |