Product Name ZKHS GDS-500D High and low temperature damping heat test Chamber HUDA QT-E702-408K60 Programmable Humidity Chamber
Product Price $9634.00 $5363.00
Details Details
Model comparison
Min-TEMP -60℃ -60℃
Max-TEMP >100℃ >100℃
Min-humidity ≤40%RH ≤20%RH
Max-humidity 98% RH 98% RH
volume ≤500L ≤500L
TEMP fluctuation ±0.5℃ ±0.5℃
Humidity deviation ±2% ±3% ±2%
Parameter comparison
Inner box Size 700*800*900mm 600*850*800mm
Temperature Range -60~150℃ -60~150℃
Humidity Control Range 30~98%RH
Temperature Fluctuation ≤±0.5℃ ≤±0.5℃
Humidity deviation +2、-3%RH ±2%RH
heating rate -20℃~ 100℃ about 35min; -40℃~ 100℃ about 45min
cooling rate 25 ℃~ -40℃ about 50min; 25 ℃~ -60℃ about 65min Average of the whole process ≥ 1 ℃/min
controller (7.0 inch) large screen screen programmable touch temperature and humidity controller
Accuracy Range Setting accuracy: temperature +/- 0.1 ℃, humidity +/- 1% R.H
Temperature and Humidity Sensor Platinum resistance PT100Ω/MV
Heating system Fully independent system, nickel-chromium alloy electric heating heater Nickel chromium alloy stainless steel heater
Humidification system Built-in isolated, all stainless steel shallow surface evaporative humidifier Stainless steel humidifier
Dehumidification system Adopt evaporator coil dewpoint temperature laminar flow contact dehumidification method
Refrigeration system Original French Mechanical binary refrigeration
circulatory system Temperature-resistant and low-noise air-conditioning motor, multi-leaf centrifugal wind turbine
Enclosure Material A3 steel plate electrostatic spraying treatment
Inner box material SUS304 stainless steel high quality mirror steel plate SUS304 #stainless steel plate (1.0mm thick)
Insulation material Polyurethane rigid foam, ultra-fine fiberglass foam
Door frame insulation Double-decked high and low temperature aging silicone rubber door sealing strip
test time 0~ 9999 M, H adjustable
Standard configuration Multi-layer heating and defrosting with lighting Glass window 1 set, test rack 2, test lead hole Φ 50mm1
Safety protection device Leakage, short circuit, over temperature, water shortage, motor overheating, compressor overVoltage, overload, overcurrent protection overall equipment overtemperature, fan overheating protection, overall equipment underphase/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment timing, leakage, operation instructions, automatic shutdown after fault alarm, etc
Power supply AC 220V +/- 10% 50Hz AC 380V +/- 10% 50Hz three-phase five-wire system
Operating Environment Temperature 5℃~+30℃ ≤85%R.H
Temperature Uniformity ≤+2℃ ±2℃